4.1
LOCATION OF
COMPRESSOR
The ES-6 Series compressor package may be
placed on any level surface able to support its
weight. The unit should be bolted to a fixed mounting
surface to avoid the possibility of externally applied
forces or vibration which would disturb the piping or
wiring.
4.2
VENTILATION AND
COOLING
Select a location to permit sufficient unobstructed air
flow in and out of the compressor to keep the
operating temperature stable. The minimum distance
that the machine should be from surrounding walls is
what is needed for service and three (3) feet (0.91m)
or more from the fan air discharge end of the
compressor.
4.3
SERVICE AIR PIPING
Service air piping should be installed as shown in
Figure 4-1. A shut-off valve should be installed to
isolate the compressor from the service line. Also
notice that the service line should be equipped with
water legs and condensate drains throughout the
system.
Section 4
INSTALLATION
WARNING
"The Plastic Pipe Institute recommends
against the use of thermoplastic pipe to
transport compressed air or other com-
pressed gases in exposed above ground
locations, e.g. in exposed plant piping." (I)
Sullube should not be used with PVC piping
systems. It may affect the bond at cemented
joints. Certain other plastic materials may
also be affected.
(I) Plastic Pipe Institute, Recommendation
B, Adopted January 19, 1972.
4.4
FLUID LEVEL CHECK AND
CHANGE PROCEDURE
The Sullair air compressor is equipped with the
proper amount of fluid. However, it is necessary to
check the fluid level at installation. The level is
checked by looking at the fluid level sight glass
located on the end bell. See Figure 2-1.
If the sump is properly filled, the fluid level should
cover 1/4 to 1/2 of the sight glass during operation.
DO NOT OVERFILL.
WARNING
Before attempting compressor mainte-
nance, disconnect compressor from power
source and lock out power source. Isolate
compressor from line pressure by closing
recommended discharge shutoff valve and
releasing all internal pressure from com-
pressor.
ES-6 USER MANUAL