PARAMETER
Parameters
Name
PU communication
119
stop bit length.
PU communication
120
parity check
Number of PU
121
communication
retries
PU communication
122
check time interval
PU communication
123
waiting time setting
PU communication
124
CR/LF presence/
absence selection
Terminal 2 frequency
125
setting gain
frequency
Terminal 4 frequency
126
setting gain
frequency
PID control
automatic
127
switchover
freqeuncy
128
PID action selection
PID proportional
129
band
130
PID integral time
131
PID upper limit
132
PID lower limit
133
PID action set point
134
PID differential time
Commercial power-
supply switchover
135
sequence output
terminal selection
MC switchover
136
interlock time
137
Start waiting time
Commercial power-
supply operation
138
switchover selection
at an alarm
Automatic
switchover
frequency between
139
inverter and
commercial power-
supply operation
Backlash
140
acceleration
stopping frequency
Backlash
141
acceleration
stopping time
*1
Setting of "9" can be made for the 01800 or more.
14
Setting Range
Initial Value
0, 1, 10, 11
1
0, 1, 2
2
0 to 10, 9999
1
0, 0.1 to 999.8s,
9999
9999
0 to 150ms,
9999
9999
0, 1, 2
1
0 to 400Hz
50Hz
0 to 400Hz
50Hz
0 to 400Hz,
9999
9999
10, 11, 20, 21,
10
50, 51, 60, 61
0.1 to 1000%,
100%
9999
0.1 to 3600s,
1s
9999
0 to 100%,
9999
9999
0 to 100%,
9999
9999
0 to 100%,
9999
9999
0.01 to 10.00s,
9999
9999
0, 1
0
0 to 100s
1s
0 to 100s
0.5s
0, 1
0
0 to 60Hz,
9999
9999
0 to 400Hz
1Hz
0 to 360s
0.5s
Parameters
Name
Backlash
142
deceleration
stopping frequency
Backlash
143
deceleration
stopping time
Speed setting
144
switchover
PU display language
145
selection
Stall prevention level
148
at 0V input.
Stall prevention level
149
at 10V input.
Output current
150
detection level
Output current
151
detection signal
delay time
Zero current
152
detection level
Zero current
153
detection time
Voltage reduction
154
selection during stall
prevention operation
RT signal reflection
155
time selection
Stall prevention
156
operation selection
OL signal output
157
timer
AM terminal function
158
selection
Automatic
switchover ON range
159
between commercial
power-supply and
inverter operation
User group read
160
selection
Frequency setting/
161
key lock operation
selection
Automatic restart
after instantaneous
162
power failure
selection
First cushion time for
163
restart
First cushion voltage
164
for restart
Stall prevention
165
operation level for
restart
Output current
166
detection signal
retention time
Output current
167
detection operation
selection
Setting Range
Initial Value
0 to 400Hz
1Hz
0 to 360s
0.5s
0, 2, 4, 6, 8, 10,
102, 104, 106,
4
108, 110
0 to 7
1
0 to 120%
110%
0 to 120%
120%
0 to 120%
110%
0 to 10s
0s
0 to 150%
5%
0 to 1s
0.5s
0, 1
1
0, 10
0
0 to 31, 100,
0
101
0 to 25s, 9999
0s
1 to 3, 5, 6,
8 to 14, 17, 21,
1
1
24, 50, 52, 53 *
0 to 10Hz, 9999
9999
0, 1, 9999
9999
0, 1, 10, 11
0
0, 1, 10, 11
0
0 to 20s
0s
0 to 100%
0%
0 to 120%
110%
0 to 10s, 9999
0.1s
0, 1
0

Hide quick links:

Advertisement

loading