Chapter 5
Certification
Agency
ETSI
UL/CSA
ATEX
Section 5.3
MIL-STD Ratings
Test
IEC 60068-2-11
MIL-STD-810E
Section 5.4
IEEE 802.16e Mobile WiMAX Compliance
The IEEE802.16-2005 specifications describe a Point-to-Multipoint (PMP) broadband wireless access standard
for systems. This standard includes descriptions for both the Media Access Control (MAC) and the physical
(PHY) layers.
The device is compliant to the IEEE802.16-2005 WiMAX forum Wave 2 profile.
NOTE
The RUGGEDCOM WIN1010 WIN product family is designed to comply with a specific revision of the
IEEE 802.16e standards, which are subject to amendment.
Section 5.5
Environmental Type Tests
Test
IEC-60068-2-1
IEC-60068-2-2
IEC-60068-2-14
IEC 60068-2-30
IEC 60068-2-18
32
Standards
ETS 300 019
Class I Div II, UL 1604,
CSA 22.2 No213-M1987
Zone 2 EN60079-0, EN60079-15
Description
SALT FOG
Description
LOW TEMP
HIGH TEMP
TEMP CHANGE
HUMIDITY (Cycling)
WATER: Rain (intensity)
RUGGEDCOM WIN5214
Installation Guide
Comments
Approved
Approved
Approved
Test Levels
5% NaCI 35° 48h
Test Levels
-40 °C
Duration: 16h
60 °C
Duration: 16h
-10 to 45 °C
0.5 °C/min
Duration: 2 cycles
30°C 90-100%
Duration: 2 cycles
0.01m3/min, 90kPa, 30min
MIL-STD Ratings