Troubleshooting
Troubleshooting
To avoid injury due to unexpected machine operation
initiated by a remote controller, disconnect the
customer I/O cable from the system prior to
troubleshooting.
ADM Error Code Table
When an error occurs, press
nance screen and press
The last digit of the error code indicates the melter, gun, or hose to which the error applies. The "_" (underscore)
character indicates the code applies to multiple items.
Last Digit in Code
0
1
2
3
4
5
6
7
8
9
A
B
C
An alarm will disable the heating system and pump. A deviation or advisory with not disable the heating system and
pump.
Code
Description
A4D0
High Current
Melter
A4D_
High Current
Hose X
A4D_
High Current
Gun X
40
to acknowledge the error. If a Maintenance error occurs, navigate to the Mainte-
to clear the error.
Code Relates to:
Melter
Gun 1
Hose 1
Gun 2
Hose 2
Gun 3
Hose 3
Gun 4
Hose 4
Gun 5
Hose 5
Gun 6
Hose 6
Type
Cause
Alarm
Band heater or rod heater.
Alarm
Hose power wires.
Alarm
Heater rods in gun manifold.
Solution
Measure resistance to ground between
heater leads. Replace band heater or rod
heater. See Replace Band Heater (page 60),
or Replace Rod Heater (page 62).
Check heater resistance and resistance to
ground. Replace heated hose.
Check heater resistance and resistance to
ground. Replace gun manifold.
3A2347ZAA