Sony MZ-N707 OpenMG Jukebox NOTES on installing & operating Service Manual page 15

Minidisc & dat walkman: portable minidisc recorder
Hide thumbs Also See for MZ-N707 OpenMG Jukebox NOTES on installing & operating:
Table of Contents

Advertisement

5. The display changes a shown below each time the
[MENU]
key is pressed.
• Address & Adjusted Value Display
Set LCD display
0 11
address
item number
• Jitter Value & Adjusted Value Display
Set LCD display
0 11
jitter value
item number
• Block Error Value & Adjusted Value Display
Set LCD display
0 11
block error value
item number
• ADIP Error Value & Adjusted Value Display
Set LCD display
0 11
ADIP error value
item number
• Focus Drive Value & Adjusted Value Display
Set LCD display
0 11
Focus drive value
item number
• Item Title Display
Set LCD display
0 11
item title
item number
However in the power mode (item number 700's), only the
item is displayed.
6. Quit the manual mode, and press the
the test mode (display check mode).
OVERALL ADJUSTMENT MODE
Mode to adjust the servo automatically in all items.
Normally, automatic adjustment is executed in this mode at the
repair.
For further information, refer to "SECTION 5 ELECTRICAL
ADJUSTMENTS" (see page 19).
adjusted value
adjusted value
adjusted value
adjusted value
adjusted value
adjusted value
/
key to return to
x
CHG
SELF-DIAGNOSIS RESULT DISPLAY MODE
This set uses the self-diagnostic function system in which if an
error occurred during the recording or playing, the mechanism
control block and the power supply control block in the
microcomputer detect it and record its cause as history in the
nonvolatile memory.
By checking this history in the test mode, you can analyze a fault
and determine its location.
Total recording time is recorded as a guideline of how long the
optical pickup has been used, and by comparing it with the total
recording time at the time when an error occurred in the self-
diagnosis result display mode, you can determine when the error
occurred.
Clear both self-diagnosis history data and total recording time, if
the optical pickup was replaced.
• Self-Diagnosis Result Display Mode Setting Method
1. Set the test mode (see page 13).
2. In the display check mode, press the
self-diagnosis result display mode where the LCD display as
shown below.
Set LCD display
0 XX
history code
error display code
3. Then, each time the
>
key is pressed, LCD display descends
by one as shown below. Also, the LCD display ascends by one
when the
.
key is pressed.
XX
: Error code
: Total recording time
[MENU]
If the
key is pressed with this display, the LCD switches
to the simple display mode.
4. Quit the self-diagnosis result display mode, and press the
key to return to the test mode (display check mode).
CHG
MZ-N707
[MENU]
key activates the
Total recording time
when error occurred
1
0 XX
0 XX
0 XX
0 XX
0 XX
1
/
x
15

Advertisement

Table of Contents
loading