¢ Wall mounted type
Unit: kBtu/h, °F
• TC: Total Capacity (kBtu/h), SHC: Sensible Heat Capacity (kBtu/h).
• The data is based on the following conditions.
• Pipe length: 24.6 ft (7.5 m), Height difference: 0 ft (0 m) [Outdoor unit - Indoor unit]
MODEL: ASU7RLF1
Outdoor temperature
(°FDB)
TC
14.0
5.88
23.0
5.88
32.0
5.88
41.0
5.88
50.0
5.88
59.0
5.88
67.0
5.88
77.0
5.88
87.0
5.88
95.0
5.88
104.0
5.11
115.0
4.35
MODEL: ASU9RLF1
Outdoor temperature
(°FDB)
TC
14.0
7.53
23.0
7.53
32.0
7.53
41.0
7.53
50.0
7.53
59.0
7.53
67.0
7.53
77.0
7.53
87.0
7.53
95.0
7.53
104.0
6.55
115.0
5.57
MODEL: ASU12RLF1
Outdoor temperature
(°FDB)
TC
14.0
10.04
23.0
10.04
32.0
10.04
41.0
10.04
50.0
10.04
59.0
10.04
67.0
10.04
77.0
10.04
87.0
10.04
95.0
10.04
104.0
8.73
115.0
7.42
6-2. Cooling capacity
64.0 / 54.0
70.0 / 60.0
SHC
TC
SHC
4.12
6.65
4.70
4.12
6.65
4.70
4.12
6.65
4.70
4.12
6.65
4.70
4.12
6.65
4.70
4.12
6.65
4.70
4.12
6.65
4.70
4.12
6.65
4.70
4.12
6.65
4.70
4.12
6.65
4.70
3.12
5.78
3.55
2.25
4.92
2.57
64.0 / 54.0
70.0 / 60.0
SHC
TC
SHC
5.27
8.51
6.01
5.27
8.51
6.01
5.27
8.51
6.01
5.27
8.51
6.01
5.27
8.51
6.01
5.27
8.51
6.01
5.27
8.51
6.01
5.27
8.51
6.01
5.27
8.51
6.01
5.27
8.51
6.01
3.99
7.40
4.55
2.89
6.29
3.29
64.0 / 54.0
70.0 / 60.0
SHC
TC
SHC
6.60
11.34
7.52
6.60
11.34
7.52
6.60
11.34
7.52
6.60
11.34
7.52
6.60
11.34
7.52
6.60
11.34
7.52
6.60
11.34
7.52
6.60
11.34
7.52
6.60
11.34
7.52
6.60
11.34
7.52
4.99
9.87
5.69
3.61
8.39
4.12
Indoor temperature (°FDB / °FWB)
75.0 / 63.0
80.0 / 67.0
TC
SHC
TC
SHC
7.01
5.41
7.50
6.08
7.01
5.41
7.50
6.08
7.01
5.41
7.50
6.08
7.01
5.41
7.50
6.08
7.01
5.41
7.50
6.08
7.01
5.41
7.50
6.08
7.01
5.41
7.50
6.08
7.01
5.41
7.50
6.08
7.01
5.41
7.50
6.08
7.01
5.41
7.50
6.08
6.09
4.09
6.52
4.60
5.18
2.96
5.55
3.32
Indoor temperature (°FDB / °FWB)
75.0 / 63.0
80.0 / 67.0
TC
SHC
TC
SHC
8.97
6.92
9.60
7.78
8.97
6.92
9.60
7.78
8.97
6.92
9.60
7.78
8.97
6.92
9.60
7.78
8.97
6.92
9.60
7.78
8.97
6.92
9.60
7.78
8.97
6.92
9.60
7.78
8.97
6.92
9.60
7.78
8.97
6.92
9.60
7.78
8.97
6.92
9.60
7.78
7.80
5.24
8.35
5.88
6.63
3.79
7.10
4.26
Indoor temperature (°FDB / °FWB)
75.0 / 63.0
80.0 / 67.0
TC
SHC
TC
SHC
11.96
8.66
12.80
9.73
11.96
8.66
12.80
9.73
11.96
8.66
12.80
9.73
11.96
8.66
12.80
9.73
11.96
8.66
12.80
9.73
11.96
8.66
12.80
9.73
11.96
8.66
12.80
9.73
11.96
8.66
12.80
9.73
11.96
8.66
12.80
9.73
11.96
8.66
12.80
9.73
10.40
6.55
11.13
7.36
8.84
4.74
9.47
5.32
- 187 -
85.0 / 71.0
90.0 / 73.0
TC
SHC
TC
SHC
8.02
6.64
8.27
7.61
8.02
6.64
8.27
7.61
8.02
6.64
8.27
7.61
8.02
6.64
8.27
7.61
8.02
6.64
8.27
7.61
8.02
6.64
8.27
7.61
8.02
6.64
8.27
7.61
8.02
6.64
8.27
7.61
8.02
6.64
8.27
7.61
8.02
6.64
8.27
7.61
6.97
5.03
7.19
5.76
5.93
3.64
6.11
4.17
85.0 / 71.0
90.0 / 73.0
TC
SHC
TC
SHC
10.26
8.50
10.58
9.74
10.26
8.50
10.58
9.74
10.26
8.50
10.58
9.74
10.26
8.50
10.58
9.74
10.26
8.50
10.58
9.74
10.26
8.50
10.58
9.74
10.26
8.50
10.58
9.74
10.26
8.50
10.58
9.74
10.26
8.50
10.58
9.74
10.26
8.50
10.58
9.74
8.93
6.44
9.20
7.37
7.59
4.65
7.83
5.33
85.0 / 71.0
90.0 / 73.0
TC
SHC
TC
SHC
13.68
10.64
14.11
12.19
13.68
10.64
14.11
12.19
13.68
10.64
14.11
12.19
13.68
10.64
14.11
12.19
13.68
10.64
14.11
12.19
13.68
10.64
14.11
12.19
13.68
10.64
14.11
12.19
13.68
10.64
14.11
12.19
13.68
10.64
14.11
12.19
13.68
10.64
14.11
12.19
11.90
8.05
12.27
9.22
10.12
5.82
10.43
6.67
6. Capacity table