Page 2
NOTE: ® Names and Logo are registered trademarks of Narda Safety Test Solutions GmbH and L3 Communications Holdings, Inc. – Trade names are trademarks of the owners. If the instrument is used in any other way than as described in this User’s Manual, it may become unsafe.
Contents Page Safety requirements and instructions…..……..EC Declaration of Conformity ......... 1 General information Page 1.1 Documentation.............. 1.2 Introduction ……………....…......1.3 Standard accessories ………………………………..1.3.1 Standard accessories AMS-8063-00…………..……. 1.3.2 Standard accessories AMS-8063-01…………..……. 1.3.3 Standard accessories AMS-8063-02…………..……. 1.4 Optional accessories……………………………………. 1.5 AMS-8063………………………………………………… 1.6 Main specifications……………………………………….
Page 4
3 8063SW02 User’s guide Page 3.1 Introduction ………….........…...... 3.2 Hardware requirements ……………………………………………. 3.3 Use of the Software 8063SW02…………….………....3.4 Software installation …….……………………………………..3.5 USB-RS232 Adapter (optional) or AMS-8063-02 Interface box.. 3.6 Software 8063SW02 COM port settings …………………………. 3.7 AMS-8063 Delay command setting .....…....3.8 AW5500 Access point installtion (AMS-8063-00 only)………….
Page 5
Figures Figure Page AMS-8063-00 or AMS-8063-01 Are Monitor System..………… AMS-8063-02 receiver baseplate……..……………………….… Panel of EHP-8063………….…………………………………….. AMS-8063/WMK Wall Mounting Kit……………………………... AMS-8063/02 on AMS-8063/WMK………………………………. AMS-8063-00 or AMS-8063-01 on AMS-8063/WMK …………. Tables Table Page Technical Specifications of the AMS-8063…………………..…. General Specifications of the EHP-8063…………………..…… Technical Specifications of the EHP-8063……..……………….
Page 6
• Ground connections must not be interrupted intentionally; • To prevent the possible danger of electrocution, do not remove any covers, panels or guards installed on the device, and refer only to NARDA Service Centers if maintenance should be necessary;...
RoHS 2011/65/UE, ed anche alle norme ISO/IEC 17050-1 e 17050-2. In accordance with the Decision 768/2008/EC, compliant to the Directives EMC 2014/30/EU, Low Voltage 2014/35/EU and RoHS 2011/65/EU, also compliant to the ISO/IEC standard 17050-1 and 17050-2 Il costruttore narda Safety Test Solutions S.r.l. Socio Unico The manufacturer Indirizzo...
Page 8
This page has been intentionally left blank VIII Safety considerations...
1 – General Information 1.1 Documentation This Users Manual contains the following annexes: • A form to be returned to NARDA with the device when requesting service. • A checklist of the accessories included in the shipment. 1.2 Introduction The AMS-8063 family products are revolutionary, accurate and reliable solutions for remote and continuous monitoring of electromagnetic fields.
1.3 Standard accessories 1.3.1 Standard accessories Standard accessories included with the AMS-8063-00 are: AMS-8063-00 The baseplate includes: • EHP-8063 Field Analyzer; • EHP-8063 power supply cable • 8063-Shutter • Wi-Fi Serial Converter; • Rx/Tx cable; • FO-8053/1 optical fiber (1m); •...
Standard accessories included with the AMS-8063-01 are: 1.3.2 Standard accessories AMS-8063-01 The baseplate includes: • EHP-8063 Field Analyzer; • EHP-8063 power supply cable; • 8063-Shutter • RS232 cable; • USB-RS232 serial converter; • Rx/Tx cable; • FO-8053/1 optical fiber (1m); •...
Standard accessories included with the AMS-8063-02 are: 1.3.3 Standard accessories AMS-8063-02 The baseplate includes: • EHP-8063 Field Analyzer; • EHP-8063 power supply cable; • 8063-Shutter • Optical / Serial Converter; • Rx/Tx cable • FO-8053/1 optical fiber (1m); • FO-8063/02 external long link fiber optic cable (5m) for service •...
The AMS-8063 Area Monitor System includes: 1.5 AMS-8063 1) EHP-8063 Field Analyzer; 2) EHP-8063 plexiglass bracket; 3) EHP-8063 support pole; 4) Baseplate with data transmission and power supply devices; it is shown AMS-8063-02 in the figure below; 5) Solar panels (AMS-8063-00 and AMS-8063-01 only); 6) Battery pack and support base.
1, 2, 3, 4, 5, 6, 12, 24 Hours or exceeding threshold setting Functions Spectrum Mode; Frequency Table, AVG, RMS LOG file All operations are written in a LOG file Zoom Horizontal Firmware upgrade Remote by PC Software upgrade free, download from NARDA Web site: www.narda-sts.it General Information...
Page 16
TABLE 1-2 General Specifications of the AMS-8063 Communication Wireless LAN 802.11b 2.4 GHz (AMS-8063-00) RS 232 (AMS-8063-01) Optical Fiber converter / RS232 (AMS-8063-02) Battery pack Backup sealed Pb rechargeable battery, 12 V 32 Ah Solar panels 2x40W 17.5V (AMS-8063-00 and AMS-8063-01 only) Consumption External power supply 100…240 V, 50/60 Hz to 24 VDC, 1.25A...
EHP-8063 is housed in a small cubic housing; the bottom side panel 1.7 EHP-8063 includes an optic fiber connector, ON/OFF level switch and operation LED. EHP-8063 is managed internally with a microprocessor that controls all the main functions. Electric or Magnetic field is picked up by three sensors on the X, Y and Z orthogonal axes.
Table 1-3 Technical specifications of the EHP-8063 Electric and Magnetic Field Analyzer Electric Field Magnetic Field Magnetic Field Mode A Mode B Frequency range 9 kHz ÷ 30 MHz 9 kHz ÷ 3 MHz 300 kHz ÷ 30 MHz Measurement range @10kHz RBW 0,1 ÷...
NARDA, therefore, in case of damage to parts and/or malfunctions, contact the NARDA service center. When the instrument has to be returned to NARDA for repairs, please complete the form included in this User’s Manual, filling in all the information necessary for the service requested.
2.5 Cleaning Use a clean, soft, dry cloth to clean the instrument and the solar cells. It is suggested to replace air filter at least once a year or more frequently if needed. To clean the instrument do not use solvents, acids, cleaning fluid, turpentine, acetone or similar products which could damage it.
1. Connect and set the PC and all devices to the network. 2.6.1 Installation of AMS-8063-00 2. Install the Support base on the site to be monitored (§ 2.6.4). 3. Install the Solar panels paying attention to orienting toward south (in the northern boreal hemisphere) the solar cells (§...
2.6.2 Installation of 1. Connect and set the PC and all devices to the network. 2. Install the Support base on the site to be monitored (§ 2.6.4). AMS-8063-01 3. Install the Solar panels paying attention to orienting toward south (in the northern boreal hemisphere) the solar cells (§...
2.6.3 Installation of 1. Connect and set the PC and all devices to the network. AMS-8063-02 2. Install the Support base on the site to be monitored (§ 2.6.4). 3. Remove the Power pack cover and place the fuse (§ 2.6.6) 4.
Page 24
2.6.4 Support base, feet Install the Support base on the site to be monitored. and pole Correct readings may be conditioned by the nature of the places in which the AMS-8063 Area Monitor System is installed. The field measuring is affected by huge metallic masses or other objects that may reflect the signal, if located in the vicinity of the unit.
Page 25
Remove the bolt from the pole support, place the pole and fasten it to the base using the bolt with nut and washers. Using the supplied pole, whose characteristics have been carefully assessed, is recommended to avoid any alteration of the field to be monitored.
2.6.5.3 Install the Solar Unscrew the inside the without losing it Pan head screw PA6 black bracket completely. panel to the Support base Insert and slide the Solar panel into the fiberglass pole and position the lower support on the base Position the Solar panel and the Support base on the ground as shown and install the lower support.
Page 29
Install the lower support to the support base with the 2 pcs. Pan head machine screw X shaped M4x16mm (16), 2 pcs. Tooth washer Ø4mm (20) and 2 pcs M4 nut (22) remaining. Position the Solar panel and the Support base on the ground as shown below.
Page 30
Fasten the Solar panel by tightening the bracket screws 2-12 Installation and use...
Page 31
2.6.5.4 Solar panel wiring Remove the Power Pack cover and fuse Remove the nut from the chock of the solar panel cable. Installation and use 2-13...
Page 32
Thread the cable through the hole in the box and screw the nut to fasten the chock to the Power Pack. Place the fuse. Plug the solar panel connector. Close the Power Pack box 2-14 Installation and use...
2.6.6 Battery pack Remove the Power Pack cover wiring and fuse (AMS-8063-02 only) Remove the nut from the chock of the power supply cable. Installation and use 2-15...
Page 34
Thread the cable through the hole in the box and screw the nut to fasten the chock to the Power Pack. Place the fuse. Plug the power supply connector. Close the Power Pack box 2-16 Installation and use...
Page 35
2.6.7 Baseplate Before mounting the baseplate on the pole, unscrew the Pan head screw mounting inside the both PA6 black brackets without losing it completely. Mount the receiver unit on the pole. Fasten the unit by tightening the bracket screws. Installation and use 2-17...
2.6.8 Radome opening Remove the screws from the receiver baseplate to allow the Radome removing. Remove along its axis the protective case Considering that it has been designed for outdoor use and the main operations are generally performed remotely. Controls and connections are available inside the protective case as listed onward in this manual and can be reached by removing the station Radome or the power pack cover.
Page 37
2.6.9 Battery pack power Remove the nut from the chock of the power cable. cable Install the power cable by mounting the chock in the hole of the receiver baseplate, plug the power supply connector to the Data/Power supply box holding by the plastic part and check the status LEDs. Installation and use 2-19...
2.6.10 Led LEDs Both LEDs let the user know about the state of process as shown in the 8063-Shutter status following table. Table 2-1 Led 8063-Shutter status Led status LEDs Action Steady EHP-8063 recharging battery Steady Green EHP-8063 Battery recharging completed Communication between PC and EHP-8063 in progress and correct.
Switch AMS-8063-02 Interface box on using the green push-button on the 2.6.14 AMS-8063-02 front panel. Interface box Connect the Interface box to the AMS-8063-02 Area Monitor Station by fiber optic paying attention to the correct correspondence in both side. Fiber optic on Fiber optic on AMS-8063-02 interface box side AMS-8063-02 Area Monitor side...
2.6.15 Radome Insert along its axis the protective case and tight the four screws to fix the mounting Radome The AMS-8063 is usually installed outdoors where atmospheric agents, 2.6.16 Bags especially strong winds, can endanger its stability. To ensure the necessary stability under the worst possible conditions, the unit is supplied with three ballast bags that can be filled with water or sand and fastened to the base of the mast.
Battery should be recharged if the station has not to be used for a long period. Any part of the instrument can only be replaced by NARDA, therefore, in case of damage to parts and/or malfunctions, contact the NARDA service center.
Page 42
Remove the Power Pack cover. Disconnect the solar panel from the Power Pack removing the chock. Connect the provided power supply/battery charger for a complete charge. 2-24 Installation and use...
Page 43
Plug the battery charger with the proper adapter to the mains outlet before connect the multipole connector to the Power pack. Fasten the cable to the strain relief. Thread the cable through the hole in the box and screw the nut to fasten the chock to the Power Pack.
2.6.18 External power Execute the following wiring in the case an external power supply is supply requested during measurements. Remove the Power Pack cover. Disconnect the solar panel from the Power Pack removing the chock Connect the provided power supply/battery charger. 2-26 Installation and use...
Page 45
Plug the battery charger with the proper adapter to the mains outlet before connect the multipole connector to the Power pack. Fasten the cable to the strain relief. Thread the cable through the hole in the box and screw the nut to fasten the chock to the Power Pack.
Page 46
2.7 AMS-8063-00 The Wi-Fi Serial Converter changes the AMS-8063 into Wi-Fi device Operating principle through a RS-232 serial port on DB9 connector. The PC handles the AMS-8063 through the access point (AP) that allows the connection to a WLAN network. The Wi-Fi Serial Converter is supplied by the 8063-Shutter through the appropriate pin on terminal block.
Page 47
The 8063-Shutter changes the AMS-8063 into RS-232 device through a 2.8 AMS-8063-01 RS-232 serial port on DB9 connector. Operating principle The PC handles the AMS-8063 through the RS232 cable. Whenever possible, it is a good rule to install the unit at some distance from walls, buildings and other obstacles that could affect the field measuring.
Page 48
2.9 AMS-8063-02 The Optical Serial converter changes the AMS-8063 into optic device Operating principle through an optic link port; it is supplied by the 8063-Shutter through the appropriate pin on terminal block. The PC handles the AMS-8063 through the AMS-8063-02 Interface box that allows a long optical connection.
To obtain software updates, please contact your NARDA distributor or download it directly from the NARDA Web site: www.narda-sts.it . The User might have the need of administrator privileges to install and run the software in Windows 7 or Windows 10; for further information see §...
3.3 Use of the Software The procedure for the correct use of the AMS-8063 system is the following 8063SW02 • Make sure the PC meets the minimum hardware requirements; • Install the software on the PC; • If needed, install the USB-RS232 adapter (optional) on the PC; •...
Page 51
3.4 Software To install the 8063SW02 on PC from the supplied Software Media proceed as follows: installation In Computer Resources, browse the Software Media supplied. The User must have administrator privileges to install the 8063SW02 software in Windows 7 or Windows 10; right click on the program .exe file and click on “Run as administrator”...
Page 52
The installation can be aborted by clicking on Cancel. The installation folder must be specified. Click Next to confirm the default folder (recommended) or Change to modify. 8063SW02 - User’s Guide...
Page 53
The installation folder must be specified. Click Next to confirm the default folder (recommended) or Change to modify. The installing status is displayed then. 8063SW02 - User’s Guide...
Page 54
Click Finish to complete and exit the installer. The folder PMM 8063SW02 is created under All Programs with the icon 8063SW02 on desktop 8063SW02 - User’s Guide...
Page 55
Connect the USB-RS232 adapter for AMS-8063-01 or the AMS-8063-02 3.5 USB-RS232 Adapter (optional, AMS-8063-01) Interface box to the PC by USB cable and wait for the “new hardware installation” procedure. Drivers supplied with the adapter can be used as AMS-8063-02 (Interface box) well.
Page 56
In Advanced Settings select the first COM port available; click OK 3.6 8063SW02 Select the icon 8063SW02 with the right mouse button COM port settings Select Properties; Add the command COMM=N preceded by a space (in capital letters) at the end of the Destination field where N indicates the serial port to be used;...
The software allows to query continuously and cyclically a system of AMS- 3.7 AMS-8063 delay § 3.9.8 EXECUTE); 8063 monitoring stations ( Command setting To set the querying delay time among AMS-8063 installed and enabled proceed as follows: Select the icon 8063SW02 with the right mouse button Select Properties;...
Page 58
Set the IP address on the PC as shown below and confirm with OK: Once again, open the settings Access Point window and click Row 1 twice. The Password field must be left empty; click on Authorize On the web browser, enter the IP address of the device on the URL (http://10.0.50.200).
Page 59
Once the user logins, the overview screen appear as shown in figure below. Select Regular AP and click on Save Settings and Apply to go to the next step. Set the Basic settings as shown in figure below. Click on Save Settings and Apply to go to the next step.
3.9 STE02W Set the IP address on the PC as shown below and confirm with OK: WiFi Serial Converter installation (AMS-8063-00 only) Run the Ste02W SETUP software and continue to click Avanti until the Pronto per l’installazione screen appear; confirm with Installa. Confirm with SI when the RealPort driver installation message appear.
Page 61
Verify the virtual COM port assigned. Set the network setting as shown in figure below: Enter in Peripheral management (Start > Settings> Control Panel > System>Hardware> Device Manager). The assigned STE02W COM port can be found in Ports (COM & LPT) – USB Serial Port (COMx). Select the COM port in order to the 8063SW02 station control panel.(see §...
3.10 Starting the program Before to start 8063SW02, it is recommended to limit the applications running on your computer. The User must have administrator privileges to run the 8063SW02 software in Windows 7 or Windows10; right click on the program .exe file and click on “Run as administrator”...
3.11 Main window The program 8063SW02 main window will be shown Fig. 3-1 8063SW02 main window 1. Tool bar; 2. Setting menu; 3. Station control panel; 4. Frequency table; 5. Scan button; 6. Execute button; 7. Undo button; 8. Exit button. 8063SW02 - User’s Guide 3-15...
3.11.1 Tool bar The tool bar shows the icon and name of the software; it is also displayed the name of the AMS-8063 system loaded on the station control panel. The control buttons allow to minimize to icon, enlarge/restore the main window and exit the program.
3.11.3 Option Option menu: Aspect Sort by date 3.11.3.1 Aspect Aspect concerns the appearance of the program: Buttons and labels styles can be selected from a Style list Start and End Color buttons allow selection from a color palette Sample Button and Sample Label show the appearance preview Default button to set appearance to the default parameters 8063SW02 - User’s Guide 3-17...
3.11.3.2 Sort by date If Sort by date is disable the frequency table saved are sorted in ascending alphabetical order. If Sort by date is enabled √ the frequency table saved are sorted in chronological order. 3-18 8063SW02 - User’s Guide...
3.11.4 Settings Settings menu: - Frequency Table - Measure 3.11.4.1 Frequency Table The Frequency table function opens a window to edit the centre frequency (in MHz) and select the Resolution Bandwidth filter. The RBW affects the sweep time (the higher RBW, the faster sweep) and frequency resolution (Lower RBW shows more details in the frequency axis).
Page 68
The Save button opens the following window: ← List Frequency table previously saved. ← Type name Frequency table (If any name is not entered, the new frequency table will be saved with the default name Table). Select Save to confirm. If select Exit, the operation will be aborted.
Page 69
Load button allows to recall a Frequency Table previously saved: ← List of the Frequency table available. Select a Frequency table from the list and confirm with Load. As long as a Frequency table is not selected, the “Load” button is disabled Click the Exit button to go back to the main window 8063SW02 - User’s Guide...
Table Mode Table Mode section allows to set different acquisition modes and the storing Rate. Field Select Electric (E) and/or Magnetic (H) in two different ranges. E 9 kHz – 30 MHz H (Mode A) 9 kHz – 3 MHz H (Mode B) 300 kHz –...
Spectrum Mode Settings F. Start MHz, F. Stop MHz: can be set to easily define frequencies to be displayed. RBW: the RBW filter is set automatically, depending on the frequency range. Threshold: The spectrum analysis is executed when exceeding the threshold value set for the field intensity.
Preamplifier Preamplifier: for best sensitivity when activated. Trace Trace to set trace colours by means of the colour palette Select the separator character (tab or comma or semicolon) to set the Text file Separator separator character between each column in the TXT file. - tab - comma - semicolon...
Save Bitmap/Save jpg It allows to define the quality of the image copied in the graph area. In the Factor Quality window drag the slider arrow left or right to change the balance between size and quality; you can also use the box to set the exact percentage.
3.11.5 Station control The Station control panel includes the list of all AMS-8063 installed. panel To enter a new Station proceed as follows: Comm: Select the COMM port available. Comment: Type the name of the monitoring station. On the “Enabled” column of the control panel, tick √ the station to be queried.
3.11.6 File File menu: - Save Panels; - Open Panels; - Open Scan (see Chapter 4). - Info 3.11.6.1 Info Click Info to display the software release currently installed on the PC 3.11.6.2 Save Panel Save Panels allows to save the group of all AMS-8063 listed to a file. ←...
3.11.6.3 Open Panels Open Panels allows to recall a group of AMS-8063 previously saved ← List of the System available. Select a System from the list and confirm with Load. As long as a System is not selected, the “Load” button is disabled Click Exit to go back to the main window 8063SW02 - User’s Guide 3-29...
3.11.7 SCAN SCAN: requests instantaneous field value (single query – not continued). With √ enable the station to be queried (which turns blue). Press SCAN button to query the station enabled. Depending on the settings (see Settings/Measure), it will be displayed the spectrum of the Electric and/or Magnetic field with automatic generation of graph (.JPG or .BMP) and table (.TXT).
3.11.8 EXECUTE With EXECUTE button t he software query continuously and cyclically a system of AMS-8063 monitoring stations. To set the querying delay time among AMS-8063 enabled see § 3.7. With √ enable the station to be queried. Press EXECUTE button to query the station enabled. On the Station control panel will be displayed new indicators as: - Last link time: date of the latest connection made;...
Page 81
- H A/m: show the instantaneous magnetic field value; simply move the mouse cursor above the value to display some frequencies and value previously read by the station. When the field exceeds the threshold set, the value will be displayed in red with asterisks (*).
Page 82
If a station is not connected or the communication is not established, the row turns red; the EHP-8063 will automatically switch off after about 3 minutes and the battery will be charged. The connection is reestablished, when the battery voltage will be above 3,05 V.
Page 83
3.11.9 8063SW02 For each station the 8063SW02 performs a continued and cyclical check; Once the connection between PC and Station is established the software Operating principle will show the Serial Number, the date of the latest connection, the battery voltage and the measured instantaneous electric and magnetic field value. Move the mouse cursor above the serial number to display the firmware release currently installed on the station.
Page 84
3.12 Uninstalling It is possible to remove the 8063SW02 software from the PC according to Software the following procedure: Exit from the 8063SW02 program. Select Start ( ) All Programs PMM 8063SW02 and then click on Uninstall PMM 8063SW02. Follow the uninstaller instructions The software is now removed from the system;...
3.13 Uninstalling the Apply this method if the driver uninstaller (normally supplied with the driver of RS232- hardware) is not available. USB adapter (optional) Right click on Computer icon to access Properties Select Hardware and Device Manager. Click to expand Porte (COM e LPT). Right click on Prolific USB-to-Serial Comm Port (COMx) and Uninstall.
Page 86
This page has been intentionally left blank 3-38 8063SW02 - User’s Guide...
Page 88
- Test: This folder contains all data acquired and the Log file. (020WJ80406). When a new monitoring station is installed, a new folder is created in the Test directory. The folder is created to collect the data every time the AMS-8063 station is queried, dividing them by year (2008), month (12) and day (19).
Page 89
- Log: All activities requested by manual interventions of the user or done automatically by the AMS-8063 are registered into a file whose name corresponds to the day that the event occurred. The Log folder collects the “day” file dividing them by year (2008) and month (12).
4.3 Data display 4.3.1 Main commands 4.3.1.1 Open Scan In the File menu, the Open Scan function allows: - Display the data recorded in graph and table format (Data folder). - Open the Log file where all activities are registered (Events folder). Data folder ←...
Page 91
List of filename extension includes: - SPC [Spectrum] (*.SPC). Properties file. - JPG [Joint Photographic Experts Group] (*.JPG). jpeg image file - BMP [BitMaP] (*.BMP). bitmap image file - TXT [Text] (*.TXT) Text file The list of file available will be displayed in order to the type of extension selected: Select the file and confirm with Open.
The Electric and/or Magnetic field value acquired in Spectrum mode will be Structure of the .TXT file stored in text format (see Settings/Measure/Spectrum Mode/Settings). The .TXT file name shows the type of the field acquired and at which Hour, Minute and Second of the day it was detected. SM_E_10_38_09.txt An example of file name is = Spectrum mode...
The Spectrum analysis of the Electric and/or Magnetic acquired field will be Structure of the stored in graph format (PCM and BMP or JPG file format). See .JPG, .BMP and .PCM file Settings/Measure/Spectrum Mode/Settings. The file name shows the type of the field acquired and at which Hour, Minute and Second of the day it was detected.
The Electric and/or Magnetic field value acquired in Table mode will be Structure of the Table.mode.txt file stored in the Table.mode.txt file used by all station. The Reading parameter indicates the number of the value read in the time interval set (Rate). Table_mode.txt preview: Data display...
Event folder The Open scan function also allows to display the Log file where all activities requested by the user or done automatically by the AMS-8063 are registered. Follow the path: Log/Year/Month and select the day. Select TXT (Text) filename extension. Must be selected TXT (Text) because all events are stored in text file.
Page 96
File Log preview: A column: Data event (Year/Month/Day); B column: Time event (Hour.Minute.Second); C column: Three asterisks (***) will be displayed if a problem occur at the station; D column: Description of the event; E column: Serial number of the station. The horizontal line is shown when the software is closed.
NARDA service center. When the instrument has to be returned to NARDA for repair, the User is kindly requested to fill out the questionnaire enclosed with this User’s Manual and write all the required service information and a full description of the malfunction, to enable NARDA to repair the device in the shortest possible time.
AMS-8063/WMK is an easy to install kit to transform the well-known AMS- 5.6 Installation 8063 Area Monitor System, usually adopted for ground installation, in a version designed to be mounted on the wall: 1. Remove the four screws and take off along its axis the protective case from the monitoring unit.
Page 100
7. Remove the metallic bracket from the receiver baseplate unscrewing the four countersunk screws, nut and washers. AMS-8063/WMK Wall Mounting Kit...
Page 101
8. Remove the metallic bracket (it will be fixed on the wall) from the AMS- 8063/WMK kit unscrewing the Pan head screw inside the both PA6 black brackets without losing it completely; remove the PA6 black bracket from the same bracket as shown below. Install the AMS-8063/WMK Wall Mounting Kit on the receiver baseplate.
Page 102
9. Fix the metallic bracket on the wall by the wall plug, washer and nut provided with the AMS-8063/WMK Wall Mounting kit. 10. Install the PA6 black bracket previously removed. AMS-8063/WMK Wall Mounting Kit...
Page 103
11. Insert and slide the pole of the AMS-8063/WMK into the both PA06 wall bracket; fasten the unit by tightening the bracket screws; 12. Install the Support base close to the AMS-8063 Area Monitor system; whenever possible install the Solar panels (AMS-8063-00 and AMS- 8063-01 only) paying attention to orienting toward south (in the northern boreal hemisphere) the solar cells;...
Page 106
Box C contains the monitoring unit with radome. Packaging instructions...
Page 107
Box D (main box) Insert Box B in the Box D Packaging instructions...
Page 108
Insert Box C in the Box D Insert the solar panels (twin pair) in the Box D. (AMS-8063-00 and AMS- 8063-01 only). Packaging instructions...
Page 109
Box D (main box) packing Use pallet and straps for the final packing Packaging instructions...
Page 110
This page has been left blank intentionally Packaging instructions...
Page 111
Moreover, we are continuously improving our quality, but we know this is a never ending process. We would be glad if our present efforts are pleasing you. Should one of your pieces of NARDA equipment need servicing you can help us serve you more effectively filling out this card and enclosing it with the product.