Iiyama Vision Master Pro 413 Service Manual page 13

17-inch color monitor
Hide thumbs Also See for Vision Master Pro 413:
Table of Contents

Advertisement

E. Repeat step C & D..
5. Purity Adjustment
A. Be sure that the display is not being exposed to any external magnetic fields.
B. Ensure that the spacing between the Purity, Convergence, Magnet, (PCM), assembly and the CRT
stem is 29mm .(See below diagram)
C. Produce a complete, red pattern on the display. Adjust the purity magnet rings on the PCM assembly
to obtain a complete field of the color red. This is done by moving the two tabs in such a manner that
they advance in an opposite direction but at the same time to obtain the same angle between the two
tabs, which should be approximately 180'.
D. Check the complete blue and complete green patterns to observe their respective color purity. Make
minor adjustments if needed.
RELATIVE PLACEMENT OF TYPICAL COMPONENTS
6. Convergence adjustment
A. Produce a magenta crosshatch on the display.
B. Adjust the focus for the best overall focus on the display.
Also adjust the brightness to the desired condition.
C. Vertical red and blue lines are converged by varying the angle between the two tabs of the 4 pole
magnets on the PCM assembly. (See above diagrams)
D. Horizontal red and blue lines are converged by varying the two tabs together, keeping the angle
between them constant.
E. Produce a white crosshatch pattern on the display.
F. Vertical green and magenta lines are converged by varying the angle between the two tabs of the 6-
pole magnets.
G. Horizontal green and magenta lines are converged by varying the two tabs together, keeping the
angle between them constant.
Purity Magnets
6-pole Convergence Magnets
4-pole Convergence Magnets
Deflection Yoke
.!22!.

Hide quick links:

Advertisement

Table of Contents
loading