Hbh Series Nomenclature - Heat Controller HBH Series Engineering Design Manual

Commercial horizontal packaged water source heat pump, 6-10 tons
Table of Contents

Advertisement

Engineering Design Guide
HBH Large Model Structure
1
2
3
HB
H
Model Type
HB = Heat Controller Compact
Configuration
H = Horizontal
Unit Size
072
096
120
Revision Level
A = Current Revision
Voltage
3 = 208-230/60/3
4 = 460/60/3
5 = 575/60/3
Basic Unit Description:
The basic unit price includes sealed heat pump refrigerant circuit
and air handler within cabinetry, fi lter, and a factory installed hang-
er kit on horizontal units.
• Cabinetry - Compact design - galvanized steel construction -
FPT water connections, high and low voltage knockouts - fi lter
and fi lter brackets. All horizontal units have fi eld convertible
discharge air patterns, no extra parts required.
• Standard Controls - CXM Controller, loss of charge switch, high
pressure switch, water coil low temperature cutout, lockout
safety circuit reset at thermostat or disconnect, LED fault indi-
cation, fi ve minute anti-short cycle, random start, high and low
voltage protection, condensate overfl ow protection, dry contact
for alarm.
• Compressor - High effi ciency scroll compressor - overload
protected.
• Refrigerant Circuit - Dual refrigerant circuit. Thermostatic ex-
pansion valve's for refrigerant metering, copper tubing intercon-
necting all components - sealed & tested non-ozone depleting,
R-410A refrigerant circuit with high and low-side Schrader ports.
4 5 6
7
9
0 9 6
A
4
C
Controls
C = CXM
HBH SERIES
10
11
12
13
14
3
A
C
S
L
Supply Air Flow Configuration
S = Straight Supply
B = Back Supply
Return Air Flow Configuration
L = Left Return
R = Right Return
V = Left Return, S.S. Drain Pan
W = Right Return, S.S. Drain Pan
Heat Exchanger Options
C = Copper Water Coil, Non Coated Air Coil
N = Cupro-Nickel Water Coil, Non Coated Air Coil
A = Copper Water Coil, E-Coated Air Coil
J = Cupro-Nickel Water Coil, E-Coated Air Coil
Blower Drive Package
A = Standard RPM & Standard Motor
B = Low RPM & Standard Motor
C = High RPM & Standard Motor
D = Standard RPM & Large Motor
E = High RPM & Large Motor
Cabinet
1 = Commercial Extended Range
2 = Commercial Extended Range w/UltraQuiet
3 = Commercial Standard Range
4 = Commercial Standard Range w/UltraQuiet
• Reversing Valve - 4-way, pilot operated, solenoid activated in
cooling.
• Water to Refrigerant Coil - Tube-in-tube, convoluted copper
inner water tube.
• Refrigerant to Air Coil - Lanced aluminum fi ns on rifl ed copper
tubes.
• Blower Motor - Belt drive with adjustable sheave, single blower
and single blower motor.
• Application - Units can be applied in WLHP, GWHP or GLHP
applications.
• Field Connections - For supply, return and condensate can be
made on either side (plug opposite side). Condensate connec-
tion on end opposite compressor end.
5
Heat Controller, Inc.

HBH Series Nomenclature

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hbh096Hbh120Hbh072