Replacement Parts - Sony KDL-V26XBR1 Operating Instructions (KDLV40XBR1) Operating Instructions Manual

Lcd digital color tv hd-tv
Hide thumbs Also See for KDL-V26XBR1 Operating Instructions (KDLV40XBR1):
Table of Contents

Advertisement

Preventing the TV from toppling over
Take measures to prevent the unit from toppling over and causing injury.
To prevent the unit from toppling over, secure the unit to the wall or
pillar.
Installing on a level surface
If you install the unit on a non-level surface, the unit
may fall or drop and cause injury or damage.
Placing on a stable surface
If you place the unit on an unstable surface, the unit
may fall and cause injury or damage.
Fall
Do not hang anything on the unit.
The unit may fall from the stand or wall-mount
bracket, causing damage or serious injury.
AC power cord
Unplug the AC power cord when moving the unit.
Do not move the unit with the AC power cord
plugged in. It may damage the AC power cord and
result in fire or electric shock.
Do not allow anything to rest on or roll over the
power cord, and do not place the unit where the
power cord is subject to wear or abuse.
Antennas
Outdoor Antenna Grounding
If an outdoor antenna is installed, follow the precautions below. An
outdoor antenna system should not be located in the vicinity of overhead
power lines or other electric light or power circuits, or where it can come
in contact with such power lines or circuits.
WHEN INSTALLING AN OUTDOOR ANTENNA SYSTEM,
EXTREME CARE SHOULD BE TAKEN TO KEEP FROM
CONTACTING SUCH POWER LINES OR CIRCUITS AS CONTACT
WITH THEM IS ALMOST INVARIABLY FATAL.
Be sure the antenna system is grounded so as to provide some protection
against voltage surges and built-up static charges.
Section 810 of the National Electrical Code (NEC) in USA and Section
54 of the Canadian Electrical Code in Canada provides information with
respect to proper grounding of the mast and supporting structure,
grounding of the lead-in wire to an antenna discharge unit, size of
grounding conductors, location of antenna discharge unit, connection to
grounding electrodes, and requirements for the grounding electrode.
8
Antenna Grounding According to the National
Electrical Code, ANSI/NFPA 70
Ground clamps
Electric service
equipment
NEC: National Electrical Code
Lightning
For added protection for this TV during a lightning storm, or when it is
left unattended and unused for long periods of time, unplug it from the
wall outlet and disconnect the antenna. This will prevent damage to the
receiver due to lightning and power-line surges.
Service
Damage Requiring Service
Do not attempt to service the set by yourself since
opening the cabinet may expose you to dangerous
voltage or other hazards.
Unplug the set from the wall outlet and refer servicing to
qualified service personnel.

Replacement parts

When replacement parts are required, be sure the
service technician certifies in writing that he/she has
used replacement parts specified by the manufacturer
that have the same characteristics as the original parts.
Unauthorized substitutions may result in fire, electric
shock or other hazards.
Safety check
Upon completion of any service or repairs to the unit,
ask the service technician to perform routine safety
checks (as specified by the manufacturer) to
determine that the unit is in safe operating condition,
and to so certify. Ask a qualified service technician to
dispose of the unit.
Antenna lead-in wire
Antenna discharge unit
(NEC Section 810-20)
Grounding conductors
(NEC Section 810-21)
Ground clamps
Power service grounding
electrode system
(NEC Art 250 Part H)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wega kdl-v26xbr1Wega kdl-v32xbr1Wega kdl-v40xbr1