Carrier 50KC04-06 Service And Maintenance Instructions page 64

Single package rooftop electric cooling units with optional electric heat with refrigerant
Table of Contents

Advertisement

CFM
0.2
RPM
900
695
975
731
1050
769
1125
807
1200
847
1275
887
1350
928
1425
969
1500
1010
CFM
1.2
RPM
900
1215
975
1231
1050
1249
1125
1270
1200
1292
1275
1315
1350
1341
1425
1367
1500
1395
Boldface indicates field-supplied drive is required.
NOTES:
1. For more information, see General Fan Performance Notes on
page 59.
CFM
0.2
RPM
900
725
975
765
1050
806
1125
847
1200
889
1275
931
1350
974
1425
1018
1500
1061
CFM
1.2
RPM
900
1172
975
1201
1050
1231
1125
1262
1200
1275
1350
1425
1500
Boldface indicates field-supplied drive is required.
NOTES:
1. For more information, see General Fan Performance Notes on
page 59.
Table J — 50KC**05 4 Ton Vertical Supply (3 Phase)
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
0.4
BHP
RPM
BHP
0.25
818
0.37
0.30
849
0.43
0.36
880
0.49
0.42
913
0.56
0.49
948
0.63
0.57
983
0.72
0.66
1020
0.82
0.76
1057
0.92
0.87
1095
1.04
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
1.4
BHP
RPM
BHP
1.01
1298
1.21
1.08
1313
1.28
1.16
1329
1.36
1.24
1347
1.45
1.34
1367
1.54
1.44
1389
1.65
1.56
1412
1.77
1.68
1437
1.90
1.82
1463
2.04
Table K — 50KC**06 5 Ton Horizontal Supply (1 Phase)
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
0.4
BHP
RPM
BHP
0.33
840
0.46
0.40
876
0.54
0.48
912
0.63
0.57
950
0.72
0.66
988
0.83
0.78
1027
0.95
0.90
1067
1.08
1.03
1107
1.23
1.19
1148
1.39
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
1.4
BHP
RPM
BHP
1.06
1239
1.23
1.16
1267
1.34
1.28
1296
1.46
1.41
0.6
RPM
BHP
RPM
930
0.51
1032
955
0.57
1053
982
0.63
1077
1011
0.71
1103
1042
0.79
1130
1073
0.88
1158
1106
0.98
1188
1140
1.09
1219
1175
1.21
1251
1.6
RPM
BHP
RPM
1378
1.42
1454
1390
1.49
1465
1405
1.57
1478
1421
1.66
1492
1440
1.76
1509
1459
1.88
1527
1481
2.00
1547
1504
2.13
1528
2.28
2. Recommend using field-supplied fan pulley (part number
KR11AZ506), motor pulley (part number KR11HY181), and belt
(part number KR30AE041) with field-supplied drive.
Medium static 920-1303 RPM, 1.7 BHP max
High static 1208-1550 RPM, 2.9 BHP max
0.6
RPM
BHP
RPM
937
0.60
1023
970
0.68
1054
1004
0.78
1087
1039
0.88
1120
1075
1.00
1154
1112
1.13
1189
1149
1.27
1224
1187
1.43
1.6
RPM
BHP
RPM
1302
1.40
1329
1.52
2. Recommend using field-supplied fan pulley (part number
KR11AZ606) and belt (part number KR30AE037) with field-sup-
plied drive.
Medium static 1035-1466 RPM, 1.5 BHP max
64
0.8
1.0
BHP
RPM
0.66
1126
0.72
1145
0.79
1166
0.87
1188
0.96
1213
1.06
1239
1.16
1266
1.28
1295
1.41
1325
1.8
2.0
BHP
RPM
1.64
1526
1.71
1536
1.79
1547
1.89
1.99
2.11
2.23
0.8
1.0
BHP
RPM
0.75
1101
0.84
1131
0.94
1162
1.05
1194
1.18
1226
1.31
1260
1.46
1.8
2.0
BHP
RPM
BHP
0.83
0.89
0.97
1.05
1.14
1.24
1.35
1.48
1.61
BHP
1.87
1.94
2.03
BHP
0.90
1.00
1.11
1.23
1.36
1.50
BHP

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Puron r-410a

Table of Contents