CFM
0.2
RPM
900
671
975
705
1050
740
1125
776
1200
813
1275
851
1350
888
1425
927
1500
965
CFM
1.2
RPM
900
1140
975
1162
1050
1186
1125
1210
1200
1236
1275
1262
1350
1289
1425
1500
Boldface indicates field-supplied drive is required.
NOTES:
1. For more information, see General Fan Performance Notes on
page 59.
2. Recommend using field-supplied fan pulley (part number
KR11HY161)) and belt (part number KR30AE035) with field-sup-
plied drive.
CFM
0.2
RPM
900
695
975
731
1050
769
1125
807
1200
847
1275
887
1350
928
1425
969
1500
1010
CFM
1.2
RPM
900
1215
975
1231
1050
1249
1125
1270
1200
1292
1275
1315
1350
1425
1500
Boldface indicates field-supplied drive is required.
NOTES:
1. For more information, see General Fan Performance Notes on
page 59.
Table G — 50KC**05 4 Ton Horizontal Supply (1 Phase)
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
0.4
BHP
RPM
BHP
0.23
790
0.34
0.28
820
0.39
0.33
851
0.45
0.38
883
0.51
0.45
916
0.58
0.52
949
0.66
0.60
984
0.75
0.69
1019
0.84
0.78
1054
0.94
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
1.4
BHP
RPM
BHP
0.92
1210
1.10
0.99
1232
1.16
1.06
1254
1.24
1.14
1278
1.33
1.23
1302
1.42
1.33
1.44
Table H — 50KC**05 4 Ton Vertical Supply (1 Phase)
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
0.4
BHP
RPM
BHP
0.25
818
0.37
0.30
849
0.43
0.36
880
0.49
0.42
913
0.56
0.49
948
0.63
0.57
983
0.72
0.66
1020
0.82
0.76
1057
0.92
0.87
1095
1.04
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
1.4
BHP
RPM
BHP
1.01
1298
1.21
1.08
1313
1.28
1.16
1329
1.36
1.24
1347
1.45
1.34
1.44
0.6
RPM
BHP
RPM
892
0.47
982
919
0.52
1007
947
0.58
1034
977
0.65
1061
1007
0.73
1089
1038
0.81
1118
1069
0.90
1148
1102
1.00
1179
1135
1.11
1210
1.6
RPM
BHP
RPM
1276
1.28
1339
1297
1.35
1319
1.43
Medium static 770-1175 RPM, 1.2 BHP max
High static 1035-1466 RPM, 1.5 BHP max
0.6
RPM
BHP
RPM
930
0.51
1032
955
0.57
1053
982
0.63
1077
1011
0.71
1103
1042
0.79
1130
1073
0.88
1158
1106
0.98
1188
1140
1.09
1219
1175
1.21
1251
1.6
RPM
BHP
RPM
1378
1.42
1390
1.49
2. Recommend using field-supplied fan pulley (part number
KR11HY161)) and belt (part number KR30AE035) with field-sup-
plied drive.
Medium static 770-1175 RPM, 1.2 BHP max
High static 1035-1466 RPM, 1.5 BHP max
62
0.8
1.0
BHP
RPM
0.61
1064
0.67
1088
0.73
1113
0.80
1138
0.89
1165
0.97
1192
1.07
1221
1.18
1250
1.29
1280
1.8
2.0
BHP
RPM
1.47
0.8
1.0
BHP
RPM
0.66
1126
0.72
1145
0.79
1166
0.87
1188
0.96
1213
1.06
1239
1.16
1266
1.28
1295
1.41
1.8
2.0
BHP
RPM
BHP
0.76
0.82
0.89
0.97
1.05
1.15
1.25
1.36
1.48
BHP
BHP
0.83
0.89
0.97
1.05
1.14
1.24
1.35
1.48
BHP

Hide quick links: