Lennox XP16 Series Unit Information page 34

Hfc-410a
Table of Contents

Advertisement

Table 2 − Indoor Units Matchups and Subcooling Charge Levels (XP16−XXX−230−05)
Target
Subcooling
INDOOR
HEAT
MATCHUP
PUMP
Heat
Cool
+5ºF
+1ºF
XP16−024
CBX26UH−024
45
6
CBX27UH−024−2
20
7
30
CBX27UH−030−2
17
7
30
CBX32MV−024/0
20
7
30
CBX32MV−036
17
7
CBX40UHV−024
17
7
CBX40UHV−030
17
7
CBX40UHV−036
17
7
CH33−31B
31
8
CR33−30/36A/B/C
45
4
CX34−31A/B
24
7
CX34−38A/B
18
8
XP16−036
CBX26UH−036
50
5
CBX27UH−036−2
22
7
30
CBX27UH−042−2
24
11
30
CBX32M−036
22
7
CBX32MV−036
22
7
CBX32MV−048
24
11
CBX40UHV−030
22
7
CBX40UHV−036
22
7
CHARGING INFORMATION FOR MODEL XP16−XXX−230−05
Unit Charging Sticker − 580275−01, dated 12/09
INDOOR
HEAT
*Add charge
MATCHUP
PUMP
CBX40UHV−042
0
15
CBX40UHV−048
0
9
CH33−43B
1
3
CH33−48C
0
9
CH33−43C
1
3
CR33−48B/C
1
3
CX34−43B/C
1
3
CX34−50/60C
1
3
1
12
CBX26UH−048
0
0
CBX27UH−048
1
11
CBX27UH−060
1
10
CBX32M−048
CBX32M−060
0
0
CBX32MV−048
0
9
CBX32MV−060
3
0
CBX32MV−068
0
9
CBX40UHV−048
0
9
CBX40UHV−060
3
0
CH23−68
0
9
CH33−49C
0
9
CH33−50/60C
Target
Subcooling
*Add charge
Heat
Cool
+5ºF
+1ºF
24
11
3
0
24
11
3
0
13
10
2
7
37
11
2
11
37
11
2
11
49
7
0
9
29
9
2
11
29
9
2
11
XP16−048
10
8
1
4
19
9
1
4
13
14
3
3
19
9
1
4
14
9
1
11
19
9
1
4
14
9
1
11
9
8
1
11
19
9
1
4
14
9
1
11
24
10
1
12
19
9
2
5
19
9
2
5
Page 34
Target
Subcooling
INDOOR
HEAT
MATCHUP
PUMP
Heat
Cool
+5ºF
+1ºF
CH33−60D
13
8
CH33−62D
11
9
CR33−50/60C
15
7
CR33−60D
16
7
CX34−60D
14
8
CX34−62D
9
9
CX34−62C
8
9
XP16−060
CBX26UH−060
20
9
CBX27UH−060−2
10
6
30
CBX32M−060
17
6
CBX32MV−060
17
6
CBX32MV−068
15
7
CBX40UHV−060
17
6
CH23−68
37
9
CH33−50/60C
33
8
CH33−62D
16
7
CR33−50/60C
24
7
CR33−60D
24
7
CX34−62C
21
9
CX34−62D
13
7
*Amount of charge required in additional to
charge shown on unit nameplate. (Remem-
ber to consider lin
set length difference.)
e
*Add charge
0
0
1
4
0
10
0
10
1
0
1
6
1
9
4
13
2
3
1
12
1
12
2
1
1
12
2
10
1
0
1
4
0
0
0
0
2
16
1
4
XP16

Advertisement

Table of Contents
loading

Table of Contents