Table 1 − Normal Operating Pressures (Liquid
*Temperature
Model
of the air
entering the
°F (°C)*
outdoor coil.
65 (18)
75 (24)
Cooling
85 (29)
First Stage
95 (35)
(Low Capacity)
105 (41)
115 (45)
65 (18)
75 (24)
Cooling
85 (29)
Second Stage
(High
95 (35)
Capacity)
105 (41)
115 (45)
50 (10)
Heating
First Stage
40 (4.5)
(Low Capacity)
50 (10)
Heating
40 (4.5)
Second Stage
(High Capac-
30 (−1)
ity)
20 (−7)
XP16
−024
Liquid Line Pressure/Vapor Line Pressure
232 / 146
225 / 144
264 / 148
261 / 147
307 / 149
302 / 149
353 / 151
349 / 151
403 / 153
397 / 153
460 / 155
461 / 157
240 / 143
239 / 139
279 / 145
278 / 141
322 / 147
322 / 143
371 / 149
367 / 146
423 / 151
426 / 148
485 / 154
489 / 151
322 / 117
333 / 118
337 / 93
306 / 112
336 / 113
302 / 93
288 / 76
279 / 62
Page 31
10 & Suction
5 psig) (XP16−XXX−230−03)
+
+
−036
235 / 144
268 / 145
310 / 147
356 / 148
407 / 150
466 / 152
244 / 140
283 / 141
326 / 144
374 / 147
427 / 148
491 / 151
366 / 114
328 / 98
369 / 75
381 / 108
322 / 92
354 / 89
309 / 75
334 / 72
296 / 62
311 / 58
−048
−048
−060
−060
225 / 138
264 / 141
305 / 142
352 / 146
405 / 148
459 / 150
241 / 134
280 / 136
324 / 137
373 / 138
425 / 142
486 / 146
335 / 92
351 / 63
329 / 82
318 / 69
323 / 70
308 / 59