Coolant, Mixing - Volvo Penta D1 Series Operator's Manual

Hide thumbs Also See for D1 Series:
Table of Contents

Advertisement

Technical Data
Cooling System
Engine Designation
Freshwater system volume, approx.
Thermostat
Starts to open at
Fully open at
82
D1-13
D1-20
2.7 liters
3.0 liters
0.7 US gals
0.8 US gals
90±2°C
90±2°C
190-198°F
190-198°F
102°C
102°C
215°F
215°F

Coolant, Mixing

WARNING!
All coolant is hazardous and harmful to the
environment. Do not consume. Coolant is flammable.
IMPORTANT:
Always use the same type of coolant that is already in
the engine.
Different types of coolant must not be mixed with each
other.
Risk of reduced cooling function and performance by
clogging and isolation.
Coolant shall be based on Organic Acid
Technology (OAT).
Follow the mixing recommendation on the
product.
The coolant should be mixed with distilled, deionized
water. For Volvo Penta specified water requirements;
refer to Water Quality.
NOTICE! Always use "Ready Mixed" coolant if water
quality cannot be determined or if it does not fulfill
ASTM D4985.
NOTICE! Never mix more than 60% concentrated
coolant with water. A greater concentration provides
reduced cooling effect with the risk for overheating and
reduced freeze protection.
47711262 01-2019 © AB VOLVO PENTA
D1-30
D2-40
4.0 liters
6.4 liters
1.0 US gal
1.7 US gals
90±2°C
90±2°C
190-198°F
190-198°F
102°C
102°C
215°F
215°F

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D1-13D1-20D1-30D2-40D2 series

Table of Contents