Scale Removal ‐ 8
• Auger motor (only) operates
for 10 minutes
• Compressor turns on, ice is
made for 40 minutes
– Must be present to add scale remover solution
while unit is making ice
– After all 16 ounces of solution is used up, push
the Float Valve On/Off lever Down to switch the
water back on