Notes on Use

Use and storage locations
Avoid using or storing the unit in the following places:
• Where it is subject to extremes of temperature
(operating temperature: +5ºC to +40ºC (41ºF to
104ºF)).
Note that in summer the temperature in a car with the
windows closed can reach 50ºC (122ºF).
• Very damp or dusty places.
• Where rain is likely to reach the unit.
• Places subject to severe vibration.
• Near strong magnetic fields
Near transmitting stations generating
strong radio waves.
Avoid violent impacts
Dropping the unit, or otherwise imparting a violent
shock to it, is likely to cause it to malfunction.
Do not cover with cloth
While the unit is in operation, do not cover it with a cloth
or other material. This can cause the temperature to rise,
leading to a malfunction.
After use
Turn the POWER switches on the unit and camera
control unit off.
Care
If the body of the unit is dirty, wipe it with a dry cloth.
For severe dirt, use a soft cloth steeped in a small amount
of neutral detergent, then wipe dry. Do not use volatile
solvents such as alcohol or thinners, as these may
damage the finish.

Specifications

General

Power consumption
100 - 240 V AC, 50/60 Hz,
maximum 1.3 A
Peak inrush current
(1) Power ON, current probe method:
50 A (240V)
(2) Hot switching inrush current,
measured in accordance with
European standard EN55103-1:
10 A (230V)
Cable length
Maximum 750 m (φ 8.5 mm)
Operating temperature
+5ºC to +40ºC (41ºF to 104ºF)
Dimensions
200 × 124 × 365 mm
(8 × 5 × 13 7/8 in.) (w / h / d)
not including projecting parts
Mass
Approx. 5.5 kg

Input signals

REFERENCE BNC type (loop-through)
VBS/BS, 1.0 Vp-p, 75 ohms automatic
terminated
1)
RET-1/2/3
BNC type (1 each, loop-through)
VBS, 1.0 Vp-p, 75 ohms automatic
terminated
1)
PROMPTER
BNC type (loop-through)
VBS, 1.0 Vp-p, 75 ohms
1) The same signal is input to RET-3 and PROMPTER.

Output signals

VBS 1/2/3
BNC type (1 each)
VBS, 1.0 Vp-p, 75 ohms
SDI
BNC type (3)
SDI format, 270 Mbps, SMPTE 259M
(CCU-TX50)/CCIR656-III (CCU-
TX50P)
2)
Y/R-Y/B-Y video
BNC type (1 each)
Y: 1.0 Vp-p, 75 ohms
R-Y/B-Y: U.S.A. and Canada:
Europe: 525 mVp-p, 75 ohms
2)
R/G/B video
BNC type (1 each)
700 mVp-p, 75 ohms
PIX
BNC type (1)
1.0 Vp-p, 75 ohms
WF
BNC type (1)
NTSC: 714 mVp-p, 75 ohms
700 mVp-p, 75 ohms
Notes on Use / Specifications