Technical specifications
8.7 Description of Active Management Technology
8.7.5

Reset AMT with Unconfigure ME

Note
If the factory setting for the AMT PC was not changed, you can skip this chapter.
If you have already configured AMT previously, discard all previous AMT settings made in
the MEBx.
Note
Note the following points:
• All previous settings in the Management Engine are deleted.
• Correct operation in the plant may be at risk.
• Note down all the settings in the MEBx. Make the settings again as necessary following
Unconfigure.
The device continues booting in factory setting.
Procedure
1. Enable the "Unconfigure ME" entry in "Advanced > Active Management Technology
Support" in the BIOS.
2. Exit BIOS with the <F10> key.
Your entry is saved and BIOS is closed. The AMT PC starts.
3. After the start, a user prompt appears asking whether you really want to discard all the
settings in the Management Engine.
4. Confirm with "Y". On a German keyboard, this means pressing the <Z> key.
132
Operating Instructions, 02/2014, A5E32317120-AB
SIMATIC IPC547E