Safety Features - Hobart 6T28-600CL Operation And Maintenance Manual

3-phase solid state transformer-rectifiers
Table of Contents

Advertisement

OM-2244 / Operation and Maintenance Manual
DCS-600 / Series 500082 / Solid State Transformer-Rectifiers
Assembly of GPU-600 Power
MODEL
SPECIFICATION NUMBER
Voltage
Amps
Frequency
Phase
Convenience Receptacle
D.C. Voltage
Amps
Duty Cycle
Kilowatts
Model
Length
(overall)
Trailer
45.7 inches
(116.1 cm)
Stationary
35.1 inches
(89.2 cm)
Bridge
36 inches
(91 cm)

5) Safety Features

The GPU continuously monitors output values and automatically shuts down if a fault occurs in order to
minimize risks to the user, the aircraft, and the GPU.
See Sub-section 7, "Detailed Description of GPU-600 Components", for details on the types and levels of
protection provided by the control system.
December 15, 2014
ELECTRICAL DATA
6T28-600CL
DCS600T60208
DCS600S60208
DCS600B60208
INPUT
208 / 230 / 460
86 / 78 / 39
60
3
10A / 115V / 60 Hz
For ground cable size See Section 2, Figure 1
OUTPUT
28.5
600
100%
17.1
PHYSICAL / DIMENSIONS
Width
(case)
24.1 inches
(61.3 cm)
24.1 inches
(61.3 cm)
24.1 inches
(61.3 cm)
Figure 3 Specifications and Capabilities
5T28-600CL
DCS600T50380
DCS600T50380CE
DCS600S50380CE
220 / 380
82 / 47
50
3
10A / 220V / 50 Hz
28.5
600
100%
17.1
Width
Height
(overall)
(w/o cable basket)
33 inches
35 inches
(83.8 cm)
(88.8 cm)
33 inches
29.3 inches
(83.8 cm)
(74.5 cm)
34.4 inches
59.8 inches
(87.3 cm)
(151.9 cm)
6T28-600CL
DCS600T6O575
DCS600B60380
DCS600S50380
230 / 460 / 575
79 / 39 / 32
60
3
10A / 115V / 60 Hz
28.5
600
100%
17.1
Weight
(overall)
650 lbs.
(295 kg)
600 lbs.
(272 kg)
Chapter 1-1