Code 1
"Boiler"/Group 2
(cont.)
Coding in the delivered condition
Service status
24:0
"Service" not shown on the dis-
play
Filling/venting
2F:0
Venting program/filling program
disabled

"DHW"/Group 3

Select group "3" (see page 48).

Coding

Coding in the delivered condition
Enable DHW circulation pump
73:0
DHW circulation pump: "ON" ac-
cording to time program (only for
weather-compensated control unit)
"Heating circuit ..."/Group 5
Select group "5" (see page 48).
Coding
Coding in the delivered condition
Ext. operating program changeover to heating circuit
d8:0
With EA1 extension:
No operating program changeover.
Max. pump speed in standard mode
E6:...
Only for heating systems without
mixer heating circuit and low loss
header:
Maximum speed of the internal
speed-controlled heating circuit
pump in % of the max. speed in
standard mode. Value is specified
by boiler-specific parameters (only
for weather-compensated control
units).
50
Possible change
24:1
"Service" is shown on the display
(address is automatically set and
must be manually reset after a serv-
ice has been carried out)
2F:1
Venting program enabled
2F:2
Filling program enabled
Possible change
73:1
During time program
to
"ON" from once per hour for 5 min to
73:6
"ON" 6 times per hour for 5 min
73:7
Constantly "ON"
Possible change
d8:1
Operating program changeover via
input DE1.
d8:2
Operating program changeover via
input DE2.
d8:3
Operating program changeover via
input DE3.
E6:0
Maximum speed adjustable from 0
to
to 100 %
E6:100