Step 8.
Firmly place right side inner door flange against the left side inner door flange and secure with (2)
hex drive screws from step 3c. DO NOT OVER TIGHTEN SCREWS.
Step 9.
Align right side inner door to combustion chamber and verify the fastener holes of the combustion
chamber are aligned with the right side inner door slotted opening. Verify seal integrity around
combustion opening. Secure right side inner door using (2) hex drive screws from step 3b.
DO NOT OVER TIGHTEN SCREWS. Verify both left and right sides of the inner door are properly
positioned and sealed against the combustion chamber.
Step 10. Reconnect lead wires from combination thermostat/gas valve to resettable thermal switch (See
photo in step 3). Note, wire terminations are interchangeable with either resettable thermal switch
connections.
Step 11.
Replace outer jacket burner access door.
Step 12.
To resume operation, follow the instructions located on the lighting instruction label or the lighting
instructions located in the installation and operation manual.