4.2
Mounting the control box
4.2.1
To install the control box
1 Remove the front plate.
2 Hold the back plate against the wall and mark the fixation points
(2 on the top and 2 at the bottom).
NOTICE
Make sure that the marks (2 by 2) are completely level and
that their dimensions correspond to the figure below.
318 mm
3 Drill 4 holes and install 4 plugs (suitable for M5).
4 Put  the  screws  in  the  top  plugs  and  hang  the  box  on  the
screws.
5 Put the screws in the bottom plugs.
6 Fix the 4 screws firmly.
INFORMATION
It  is  possible  to  connect  the  user  interface  to  the  control
box.  For  more  information,  refer  to 
user interface" on page 6.
4.3
Connecting the electrical wiring
DANGER: RISK OF ELECTROCUTION
WARNING
ALWAYS use multicore cable for power supply cables.
4.3.1
About electrical compliance
Equipment  complying  with  EN/IEC  61000­3­12  (European/
International  Technical  Standard  setting  the  limits  for  harmonic
currents  produced  by  equipment  connected  to  public  low­voltage
systems with input current >16 A and ≤75 A per phase.).
EKCB07CAV3
Daikin Altherma low temperature monobloc control box
4P404075­1 – 2015.03
4.3.2
1 Insert the wiring from the bottom of the control box.
2 Make sure the low voltage wiring is located on the right. Route it
4.3.3
1 Connect the power supply cable to the control box.
"4.3.5  To  connect  the
2 Fix  the  cable  with  cable  ties  to  the  cable  tie  mountings  to
To connect the electrical wiring on the
control box
through the intake hole and fasten it with cable ties.
c
b
a
a
Low voltage wiring
b
High voltage wiring
c
Main power supply
NOTICE
The  distance  between  the  high  voltage  and  low  voltage
cables should be at least 25 mm.
To connect the control box power supply
X1M
1 2 3
1 2 3
1
GND
2
L
3
N
ensure strain relief and to make sure that it does NOT come in
contact with sharp edges.
CAUTION
Do NOT push or place redundant cable length in the unit.
4 Installation