Advanced Programming - Pentair SIATA V132-SFE-EV-VIRIDION Installer Manual

Table of Contents

Advertisement

6.4.3. Advanced programming

Entering the advanced menu
A
Press
and
B
Enter the password.
→ See Access password, page 49.
Relays activation mode
Note
The number lit on the upper part of the display identifies the relay to set.
Select the relay.
A
Set the relay 1 or 2 using
B
Press
to go through the parameter showed in the bellow table.
C
For each parameter use
confirm.
Parameter
C1
1st regeneration cycle.
C2
2nd regeneration cycle.
C3
3dr regeneration cycle.
C4
4th regeneration cycle.
ri
Active during whole regeneration.
Active from the end of regeneration
EC
until the programmed time (minutes).
SA
Salt alarm.
Fr
Active if the alarm FR01 is present.
AL
Active in case of generic alarm active.
B
Active during refill.
Ref. MKT-IM-009 / C - 08.06.2018
Installer Manual Siata V132-SFE-EV-VIRIDION - Programming
simultaneously for 5 seconds to access to the advanced menu.
or
.
or
to change the value and
Description
to
Characterisation
OFF to duration of 1st cycle.
OFF to duration of 2nd cycle.
OFF to duration of 3rd cycle.
OFF to duration of 4th cycle.
ON - OFF.
0 to 99 min.
OFF - ON.
OFF - ON.
OFF - ON.
OFF or rF (during refill) or rFd (during
refill & brine draw).
61 / 110