Service and maintenance

5.1

Inspection

● Inspect the RBSS periodically to ensure that it can rotate freely about the pivot pin or
cross bar.
● Inspect the proximity switch area periodically and remove any material build-up.
5.2

Unit repair and excluded liability

All changes and repairs must be done by qualified personnel and applicable safety
regulations must be followed. Please note the following:
● The user is responsible for all changes and repairs made to the device.
● All new components must be provided by Siemens Milltronics Process Instruments Inc.
● Restrict repair to faulty components only.
● Do not re-use faulty components.
5.3

Wheel and bearing repair

Case 1
For tube housings with through holes for bolt and bushings of 22 mm (7/8 inch).
Parts required:
● 1 - wheel assembly, complete with sealed bearings and 60 tooth gear
● 2 - bushings
● 1 - M12 washer (optional - see
● 2 - stepped washers
● 1 - hex head bolt M12 x 1.75, 120 mm long
● 1 - locking hex nut M12 x 1.75
Milltronics RBSS
Operating Instructions, 07/2018, A5E45419003-AA
on diagram below)
5
15