Fortinet FortiController-5103B Session-Aware Load Balancer Manual page 29

Table of Contents

Advertisement

Basic Configuration
FortiController-5103B Session-Aware Load Balancer Guide
10-500-161552-20140822
http://docs.fortinet.com/
get load-balance status
ELBC Master Blade: slot-4
Confsync Master Blade: slot-4
Blades:
Working:
3 [
3 Active
Ready:
0 [
0 Active
Dead:
0 [
0 Active
Total:
3 [
Slot
4: Status:Working
Link:
Base: Up
Heartbeat: Managment: Good
Status Message:"Running"
Slot
6: Status:Working
Link:
Base: Up
Heartbeat: Managment: Good
Status Message:"Running"
Slot
8: Status:Working
Link:
Base: Up
Heartbeat: Managment: Good
Status Message:"Running"
The command output provides the same information as the Load Balance > Status
web-based manager page, including the slot that contains the primary unit (slot 4), the
number of FortiGate-5001B boards in the cluster, the slots containing all of the
FortiGate-5001B boards (4, 6, and 8) and the status of each board. Status information
includes the status of the connection between the board and the base and fabric
backplanes, whether the heartbeat is active, the status of the board and the data
processed by the board. The status message can also indicate if the board is waiting for
a fabric connection or waiting for a base connection.
You can also use the following commands to display detailed session aware load
balancing diagnostics:
diangnose salb {dp | tcam-rules}
The dp option provides diagnostics for the FortiASIC DP processors and the
tcam-rules option provides diagnostics for content aware routing rules (TCAM).
Verifying the configuration and the status of the boards in the cluster
0 Standby]
0 Standby]
0 Standby]
3 Active
0 Standby]
Function:Active
Fabric: Up
Data: Good
Function:Active
Fabric: Up
Data: Good
Function:Active
Fabric: Up
Data: Good
29