Dr 5 General Parameters; Figure 5-4 Theoretical Adjustment With Siwatool U - Siemens Siwarex U Device Manual

Universal weighing module for simatic s7 300 and et 200m
Hide thumbs Also See for Siwarex U:
Table of Contents

Advertisement

Figure 5-4
Theoretical adjustment with SIWATOOL U

5.4 DR 5 General parameters

In DR5, parameters are specified which affect the module as a whole, i.e. which
have no connection to a measurement channel. Procedure:
Check all parameters and modify as necessary.
o
Send DR 5 to the scale
o
Name
Module numbers
Port parameters
Display type
SIWAREX U
Model
Length
Default
BYTE
1
0
BYTE
1
0
BYTE
1
0
4BWEIGHING FUNCTIONS
Range of values/Meaning
Each module can be assigned a module number.
This setting is valid both for the RS232 port and the TTY
port. The baud rate is fixed at 9600 bit/s.
Bit no.
reset
0
with parity bit (default)
1
parity even (default)
2 - 7
reserve
Code (dec)
Meaning
set
without parity bit
parity odd
5-33