Download Print this page

Siemens SIMATIC Ident Compact Operating Instructions page 7

Code reader systems
Hide thumbs Also See for SIMATIC Ident:

Advertisement

Pinout of Power IO RS-232 cable
NOTICE
INPUT - COMMON or OUTPUT - COMMON must be connected
To be able to use the inputs and outputs described below, it is imperative that the INPUT - COMMON or OUTPUT -
COMMON is connected.
Table 3-1
SIMATIC MV440
Pin
Color
Signal name
H
red
24 V DC
G
blue
0 V
K
violet
INPUT1
D
yellow
INPUT /
OUTPUT2
L
Gray/
INPUT /
pink
OUTPUT3
C
green
INPUT /
OUTPUT4
B
brown
INPUT /
OUTPUT5
A
white
INPUT -
COMMON
E
gray
OUTPUT -
COMMON
J
black
STROBE
(OUTPUT)
F
pink
RS-232 TXD
M
red/blue
RS-232 RXD
SIMATIC MV420/SIMATIC MV440
A5E02370910-06, 04/2013
Possible values
TRG
DISA, SEL0, SEL1, SEL2, SEL3, TRN,
RES, IN_OP, TRD, RDY, READ,
MATCH, N_OK, EXT_1, EXT_2,
EXT_3, EXT_4
DISA, SEL0, SEL1, SEL2, SEL3, TRN,
RES, IN_OP, TRD, RDY, READ,
MATCH, N_OK, EXT_1, EXT_2,
EXT_3, EXT_4
DISA, SEL0, SEL1, SEL2, SEL3, TRN,
RES, IN_OP, TRD, RDY, READ,
MATCH, N_OK, EXT_1, EXT_2,
EXT_3, EXT_4
DISA, SEL0, SEL1, SEL2, SEL3, TRN,
RES, IN_OP, TRD, RDY, READ,
MATCH, N_OK, EXT_1, EXT_2,
EXT_3, EXT_4
P-type inputs/outputs:
INPUT - COMMON = 0 V and
OUTPUT - COMMON = + 24 V DC
N-type inputs/outputs:
INPUT - COMMON = + 24 V DC and
OUTPUT - COMMON = 0 V
Default setting
Meaning
Power supply
Power supply
TRG
Trigger input
IN_OP
Freely selectable input
or output.
RDY
Freely selectable input
or output.
READ
Freely selectable input
or output.
N_OK
Freely selectable input
or output.
Reference point, 0 V or
24 V for inputs.
Reference point, 0 V or
24 V for outputs.
Signal output for
connecting external
strobe lights
RS-232 send line
RS-232 receive line
5

Advertisement

loading

This manual is also suitable for:

Simatic mv420Simatic mv440