Sony HDW-F900H Maintenance Manual page 71

Sony camcorder maintenance manual hdw-f900, hdw-f900h
Hide thumbs Also See for HDW-F900H:
Table of Contents

Advertisement

BATT ALARM page
<BATT ALARM>
BATT
TYPE : LITHIUM
BEFORE END : 11.5V
END
: 11.0V
DC IN
TYPE : AC ADP
BEFORE END : --
END
: --
Item
Setting
BATT TYPE
LITHIUM, DIGITAL,
OTHERS1
OTHERS2
AC ADP
BEFORE END
11.0 to 17.0 V
END
11.0 to 17.0 V
DC IN TYPE
LITHIUM, DIGITAL,
OTHERS1
OTHERS2
AC ADP
BEFORE END
11.0 to 17.0 V
END
11.0 to 17.0 V
b)
Select OTHERS1 and 2 when using the batteries other than LITHIUM, DIGITAL, AC ADP or the power supply.
c)
Select the AC ADP, when using the AC/DC power supply of AC-550/550CE.
OTHERS1 page
<OTHERS 1>
H PHASE
:
0
MONITOR OUT
Y: 0
Pb/Pr: 0
Item
Setting
H PHASE
_3072 to 1023
MONITOR OUT
Y
_30 to 30
Pb/Pr
_30 to 30
d)
Used to adjust the error resulting from variation of 75 Z termination.
Prior to adjusting the video level at MONITOR OUT, be sure to adjust video levels on the waveform monitor using a camera color-
bar.
HDW-F900 P1E2
(Display is initial values.)
Description
Selects the battery to be connected, to the battery terminal. (Same as
b)
,
the BATT ALARM page in the OPERATION menu.)
b)
,
By this setting, the battery alarm voltage indication in accordance with
c)
the features of the battery or the power supply becomes possible.
Sets the alarm voltage indicating that the battery is wearing out. When
the AC ADP is selected, this setting is unavailable, "- - -" is displayed
showing invalid.
Sets the alarm voltage indicating that the battery has worn out. When
the AC ADP is selected, this setting is unavailable, "- - -" is displayed
showing invalid.
Selects the power running in the DC IN connector. (Same as the BATT
b)
,
ALARM page in the OPERATION menu.)
b)
,
By this setting, the battery alarm voltage indication in accordance with
c)
the features of the battery or the power supply becomes possible.
Sets the alarm voltage indicating that the DC power is wearing out.
When the AC ADP is selected, this setting is unavailable, "- - -" is
displayed showing invalid.
Sets the alarm voltage indicating that the DC power has worn out.
When the AC ADP is selected, this setting is unavailable, "- - -" is
displayed showing invalid.
(Display is initial values.)
Description
Adjusts the H phase.
Sets the Y output level at MONITOR OUT (BNC).
Sets the Pb and Pr output level at MONITOR OUT (BNC).
4-7. MAINTENANCE Menu
d)
d)
4-31

Advertisement

Table of Contents