Note 5: Read Frequency & Mode Status

Power-on Microprocessor Reset Procedures

Some or all transceiver settings can be reset to their factory-default states using one of the following power-on routines:
ρ [V/M] + POWER on: Resets all memories and following menu settings to their factory-default values:
Menu #06 (AM STEP), 33 (DCS CODE), 52 (FM STEP), 56 (MEM TAG), 76 (RPT SHIFT), 82 (SSB
STEP), and 83 (TONE FREQ).
ρ [F] + POWER on: Resets all menu settings (except the following menu items) to their factory-default values.
Menu #06 (AM STEP), 33 (DCS CODE), 52 (FM STEP), 56 (MEM TAG), 76 (RPT SHIFT), 82 (SSB
STEP), and 83 (TONE FREQ).
ρ [HOME] + POWER on: CPU master reset for all memories and menu settings.
You can transfer all data stored in one transceiver to another set by utilizing the handy "Cloning" feature. This requires a
user-constructed cloning cable which connects the CAT/LINEAR jacks on the two transceivers, as shown below.
To clone from one transceiver to another, use the following procedure:
1. Insert the Clone Cable into the CAT/LINEAR jack of each transceiver.
2. Turn both transceivers off, then press and hold in the MODE(<) and MODE(>) buttons on each radio while turning
the power on again. The "CLONE MODE" notation will appear on the display.
3. On the "d estination" radio, press the [C] key.
4. Now, on the "source" radio, press the [A] key. Data will now be transferred to the "Destination" radio from the
"Source" radio.
5. If there is a problem during the cloning process, "error" will be displayed.
Check your cable connections and try again.
6. If cloning is successful, turn the "destination" radio off. Now turn the "source" radio off.
7. Remove the clone cable. Channel and operating data for both radios are now identical. They both may be turned on
now for normal operation.
1. Turn the transceiver's power off by pressing and holding in the PWR switch for one second, then disconnect the DC
cable from the INPUT jack on the rear panel of the transceiver, when operating the FT-857 with a DC power supply
or optional FP-30 AC power supply.
2. Referring to Figure 1, remove the eight screws affixing the top cover of the transceiver then disconnect the speaker's
connector from the MAIN Unit.

Installation of Optional Accessories

Optional Filters:YF-122S and YF-122C
Cloning