VISCA Camera-Issued Messages
ACK/Completion Messages
ACK
Completion
z = Device address + 8

Error Messages

Syntax Error
Command Buffer Full
Command Canceled
No Socket
Command Not Executable
Network Change Message
Network Change
Command Messages
z0 4y FF
(y:Socket No.)
z0 5y FF
(y:Socket No.)
Command Messages
z0 60 02 FF
z0 60 03 FF
z0 6y 04 FF
(y:Socket No.)
z0 6y 05 FF
(y:Socket No.)
z0 6y 41 FF
(y:Socket No.)
Comments
Command Message
Issued when power is being routed to the camera, or when the VISCA device is
z0 38 FF
connected to or disconnected from the VISCA OUT jack.
Comments
Returned when the command is accepted.
Returned when the command has been executed.
Comments
Returned when the command format is different or when a command with illegal
command parameters is accepted.
Indicates that two sockets are already being used (executing two commands) and the
command could not be accepted when received.
Returned when a command which is being executed in a socket specified by the
cancel command is canceled. The completion message for the command is not
returned.
Returned when no command is executed in a socket specified by the cancel
command, or when an invalid socket number is specified.
Returned when a command cannot be executed due to current conditions. For
example, when commands controlling the focus manually are received during auto
focus.