5.1
ensure the machine is unplugged from the power supply (fig.4.1). make sure
the tank is clean and free from dust and dirt.
5.2
remove the cartridge filter and fit a foam filter over the filter basket (fig.4.2)
replace the top section onto the container.
5.3
fit the desired nozzle to the flexible hose (fig.4.3)
5.4
ensure the switch is 'off' (position '0') before plugging into the power supply.
5.5
Press the switch to 'on' (position 'I'). (fig.4.5)
note: to vacuum large quantities of liquid, from a sink or tank etc, do not immerse
the nozzle completely in the liquid, leave a gap at the top of the nozzle
opening to allow an air inflow. the machine is fitted with a float valve which
stops the suction action when the tank has reached its maximum capacity.
the user will notice an increase in motor speed. When this happens, turn off
the machine, disconnect from power supply, remove the head from the
container and empty the liquid into a suitable receptacle or drain.
to continue vacuuming, refit the head and proceed. After wet vacuuming,
turn the machine off and unplug from power supply. empty the container, clean and dry the inside and outside
before storage.
remember! After wet vacuuming the foam filter must be removed and a cartridge filter must be fitted before dry vacuuming again.
 warnInG! not designed for liquid storage. always empty liquids after use and before storing.
6. BlOwInG
6.1
Push the large end of the flexible hose into the blow connection in the top
section. (fig.5.1)
6.2
ensure the power switch is turned off (fig.5.2) and plug in the power supply
(fig.5.3)
6.3
switch on the power (position 'I'). (fig.5.4)
6.4
the unit will now blow through the hose and can be used to clear
obstructions within the pipe. (fig.5.5)
warnInG! If after a few seconds the hose is still blocked turn of the unit and
clear the hose manually.
7. maIntenance
7.1

General maIntenance.

7.1.1 ensure the machine is unplugged from the power supply.
7.1.2 disconnect the hose from the container.
7.1.3 undo the clasps and remove motor head from the container.
7.1.4 Clear out any dirt or debris from the container and hose.
7.1.5 Clean the foam filter by washing it in a mild soapy solution.
7.1.6 Check the power cable to make sure that it is not damaged.
7.2
cartrIdGe FIlter maIntenance.
7.2.1 Handle the filter carefully when cleaning or installing.
7.2.2 unlock and carefully remove the cartridge filter (fig.6.1) and inspect it for
damage. A filter that has small holes or tears in it will not perform efficiently
and should be replaced.
7.2.3 to clean a dry filter, tap it inside a waste bin. (fig.6.2)
7.2.4 do not use the filter if it becomes wet as the filter will clog quickly and be
very difficult to clean. (the cartridge filter is designed for dry
vacuuming only). should the filter be inadvertently wetted it should be
rinsed from the inside (fig.6.2) and allowed to air dry for 24 hours.
7.2.5 fit a new/cleaned filter over the filter basket (fig.6.3) and lock in place as
described in section 4.2.
8.
trOuBleSHOOtInG
Cleaner will not operate.
dust comes from the motor cover.
reduced efficiency and increased
motor speed/vibration.
9.
cOnSumaBleS
locking Cartridge filter (must be used for dry vacuuming) . . . . . . . . . . . . . . . . . model No. PC200Cfl
foam filter (Pack of 10). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . model No. PC200ff10
ImpOrtant! IF tHe macHIne IS uSed wItHOut a FIlter FItted tHIS may cauSe damaGe tO tHe mOtOr and yOur
Guarantee wIll Be InvalIdated. alwayS Keep a Spare cartrIdGe FIlter Handy.
PC200sd dust Bags (Pack of 5) optional extra . . . . . . . . . . . . . . . . . . . . . . . . . model No. PC200PB5
fig.6
No power supply.
faulty power cable, switch or motor.
Container full of liquid.
Cartridge filter missing or damaged.
Container full.
filter clogged.
Nozzle, hose or container inlet blocked.
Original Language Version
fig.5
Check supply.
Check and repair or replace faulty item.
empty container.
fit or replace cartridge filter.
empty container.
Clean or replace cartridge filter.
Check nozzle, hose and container inlet for blockage.
fig.4