Panasonic TH-58PF12UK Service Manual page 34

High definition plasma display
Hide thumbs Also See for TH-58PF12UK:
Table of Contents

Advertisement

TH-58PF12UK
10.1.2. Initialization Pulse Adjust
1. Set Aging pattern (white pattern signal) by IIC mode.
2. Set the picture controls as follows.
Picture menu: Standard
Picture: +25
Aspect: Full
3. Connect Oscilloscope to TPSC1 and adjust VR16601 for 250V ± 10V.
TPSC1 (SC)
10.1.3. P.C.B. (Print Circuit Board) exchange
10.1.3.1. Caution
1. To remove P.C.B., wait 1 minute after power was off for discharge from electrolysis capacitors.
10.1.3.2. Quick adjustment after P.C.B. exchange
Adjust the following voltages with the multimeter.
P.C.B.
P Board
Vsus
SC Board
Vad
Vscn
Vset
SS Board
Ve
D, DS, DN Board
White balance and Sub brightness for NTSC, PAL, HD, PC and 625i signals
DN Board
Set Market Select Number to correct destination by MS mode (See chap. 6.1.4)
*See the Panel Label.
Caution
Absolutely do not reduce Vsus voltage below Ve not to damage the P.C.B.
Test Point
Volume
VR16601 (SC)
250V ± 10V
at 100 µ
Name
Test Point
TPVSUS (SS)
TPVAD (SC)
TPVSCN (SC)
TPVSET (SC)
TPVE (SS)
Level
s
period on the down slope.
Voltage
Volume
Vsus ± 2V
VR251(P)
-165V ± 2V
VR16600 (SC)
Vad_base:+145V±4V
Fixed
GND_base: -20V±6V
290V ± 9V
Fixed
Ve ± 2.5V
Fixed
34
Remarks
*
*