Erv Units Only - Broan HRV90H Series Installation Instructions Manual

Hide thumbs Also See for HRV90H Series:
Table of Contents

Advertisement

Available languages

Available languages

2.
TYPICAL INSTALLATIONS (
2.4
I
ERV U
NSTALLATION FOR
2.4.1 G
L
EOGRAPHICAL
The ERV units are created to meet specific requirements related to geographical locations. Take a look at the map below; the shaded area
shows the limits where the ERV unit can be installed. However, there is no geographical limitation for installing an HRV unit.
WHITEHORSE
ANCHORAGE
JUNEAU
Prince Rupert
VICTORIA
VN0006
NOTE: The ERV unit is designed to assist in the management of humidity introduced into the home.
During cooling season, in extreme humidity conditions, the use of additional dehumidification unit may be required to quickly
remove all excess moisture. During heating season, in extreme dryness conditions, the use of a humidifier may be required if the
indoor air is still too dry.
2.4.2 ERV U
A
NITS
TTIC
All 3 types of installations can be used in the attic (Fully ducted system, Central Draw Point or Simplified). The example shown below is a
Simplified installation (connection to a forced air system).
NOTE: To get the most of your ERV unit, the ambient temperature around the unit should be conditioned. If the unit has to be installed in
an unconditioned space, the heat gains or losses from the unit and the ducts could increase the operation costs of the unit.
• Due to the potential temperature difference between the attic and the rest of the house, all unit ducts must be insulated.
• The attic temperature must always be above 0°C (32°F) and under 65°C (149°F).
Stale air is exhausted to the outside. Fresh air from outside is filtered
and supplied to the return (plenum) of the forced air unit. See figure
at right.
To avoid cross-contamination and achieve the highest efficiencies, the
forced air system blower must always be ON.
NOTE: Home with multiple forced air systems should have 1 unit on
each system.
'
)
CONT
D
O
NITS
NLY
OCATION
YELLOWKNIFE
HAY RIVER
FORT SMITH
FORT MCMURRAY
GRANDE PRAIRIE
EDMONTON
JASPER
KAMLOOPS
CALGARY
PENTICTON
LETHBRIDGE
HELENA
OLYMPIA
SALEM
BOISE
SALT LAKE CITY
RENO
SACRAMENTO
PHOENIX
I
NSTALLATION
PRINCE ALBERT
SASKATOON
REGINA
WINNIPEG
BISMARCK
SAULT STE MARIE
ST. PAUL
MADISON
DES MOINES
DENVER
SPRINGFIELD
TOPEKA
SANTA FE
OKLAHOMA CITY
BATON ROUGE
AUSTIN
CAUTION
VH0058
8
CHIBOUGAMAU
CHICOUTIMI
TIMMINS
VAL-DOR
QUEBEC
SUDBURY
NORTH BAY
MONTRÉAL
OTTAWA
TORONTO
DETROIT
BOSTON
HARTFORD
HARRISBURG
INDIANAPOLIS
COLUMBUS
WASHINGTON
NASHVILLE
RALEIGH
COLUMBIA
ATLANTA
GOOSE BAY
LABRADOR CITY
SEPT-ILES
GASPÉ
MATANE
BATHURST
CHARLOTTETOWN
ST JOHN'S
HALIFAX
ST-JOHN

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Hrv90htHrv90hsErv90hc seriesHrv90hcsHrv90hct

Table of Contents