Yaesu FTM-350R Technical Supplement page 10

Dual band fm transceiver
Hide thumbs Also See for FTM-350R:
Table of Contents

Advertisement

Alignment
26.Increase the output level of the signal generator
up to +23 dBμV.
27.Press the [ FWD ] key to save the new setting.
28.Press and hold in the [ ADJ ] key for one second,
to set the alignment Menu Item "SMB U D
29.Just repeat all steps above, in "SUB BAND".
14
TX Deviation
1. Inject a 1 kHz, 80 mV signal from the Audio Gen-
2. Set the transceiver frequency to 440.050 MHz.
3. Press the [ POW ] key to select "LOW".
SMB U D".
SMB U D
SMB U D
SMB U D
4. Press the [ ADJ ] key to set the alignment Menu
5. Press the PTT switch to activate the transmitter,
6. Set the transceiver frequency to 146.050 MHz.
7. Press the PTT switch to activate the transmitter,
The following steps is USA Version only.
8. Set the transceiver frequency to 223.550 MHz.
9. Press the PTT switch to activate the transmitter,
CTCSS TX Deviation
1. Set the transceiver frequency to 440.050 MHz.
2. Press the [ POW ] key to select "LOW".
3. Press and hold in the [ F ] key for two seconds to
4. Press the [ TYPE ] key repeatedly, until the "TONE
5. Press the [ TFRQ ] key, then rotate the right DIAL
6. Press the [ ESC ] key to save the new setting.
7. Press the [ ADJ ] key to set the alignment Menu
8. Rotate the left DIAL knob to select "MOD 10EH
9. Press the [ ADJ ] key to set the alignment Menu
10.Press the PTT switch to activate the transmitter,
11.Set the transceiver frequency to 146.050 MHz.
12.Press the [ POW ] key to select "LOW".
13.Press and hold in the [ F ] key for two seconds to
14.Press the [ TYPE ] key repeatedly, until the "TONE
erator.
Item "DEV xxx
DEV xxx
DEV xxx
DEV xxx".
DEV xxx
adjust the left DIAL knob so that the Deviation
Meter reading is 4.5 kHz (±0.2 kHz) (USA Ver-
sion: 4.2 kHz (±0.2 kHz).
adjust the left DIAL knob so that the Deviation
Meter reading is 4.5 kHz (±0.2 kHz) (USA Ver-
sion: 4.2 kHz (±0.2 kHz).
adjust the left DIAL knob so that the Deviation
Meter reading is 4.2 kHz (±0.2 kHz).
change the [ SMART FUNCTION ] key category to
the "SQL" functions.
ENC" notation appears.
knob to select "100.0 Hz".
Item "MOD xxx
MOD xxx".
MOD xxx
MOD xxx
MOD xxx
CTC xxx
CTC xxx
Item "CTC xxx
CTC xxx
CTC xxx".
adjust the left DIAL knob so that the Deviation
Meter reading is 0.65 kHz ~ 0.75 kHz.
change the [ SMART FUNCTION ] key category to
the "SQL" functions.
ENC" notation appears.
FTM-350AR/E Technical Supplement
MOD 10EH
MOD 10EH
MOD 10EH".
MOD 10EH