Specifications; Maintenance - Snapper G1000 Owner's Manual

1000 watt ac generator
Hide thumbs Also See for G1000:
Table of Contents

Advertisement

Available languages

Available languages

SPECIFICATIONS

Rated Surge Watts . . . . . . . . . . . . . . . . . . . . . . . . 1,000 Watts
Rated Running Watts . . . . . . . . . . . . . . . . . . . . . . . . 900 Watts
Rated Maximum Current
At 120 Volts AC . . . . . . . . . . . . . . . . . . . . . . . . . .7.5 Amps
At 12 Volts DC . . . . . . . . . . . . . . . . . . . . . . . . . . .8.3 Amps
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Single Phase
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 Hertz
Packaged Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61.0 lbs.
GENERAL MAINTENANCE
RECOMMENDATIONS
The Owner/Operator is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the unit
is kept clean and properly stored. NEVER operate a
damaged or defective generator.
Engine Maintenance
See engine owner's manual for instructions.
CAUTION
Avoid prolonged or repeated skin contact with used
motor oil.
• Used motor oil has been shown to cause skin cancer in
certain laboratory animals.
• Thoroughly wash exposed areas with soap and water.
KEEP OUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.
Snapper G1000 Generator
Generator Maintenance
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.
NOTE: DO NOT use a garden hose to clean generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air
slots, some of the water will be retained in voids and
cracks of the rotor and stator winding insulation. Water
and dirt buildup on the generator internal windings will
eventually decrease the insulation resistance of these
windings.
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR
GENERATOR
• Disconnect the spark plug wire from the spark plug and place
the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
• Use approved spark plug tester.
• DO NOT check for spark with spark plug removed.
Generator Cleaning
• Use a damp cloth to wipe exterior surfaces clean.
Improper treatment of generator can damage it and
shorten its life.
• DO NOT expose generator to excessive moisture, dust, dirt,
or corrosive vapors.
• DO NOT insert any objects through cooling slots.
• Use a soft bristle brush to loosen caked on dirt or oil.
• Use a vacuum cleaner to pick up loose dirt and debris.
• Use low pressure air (not to exceed 25 psi) to blow
away dirt. Inspect cooling air slots and opening on
generator. These openings must be kept clean and
unobstructed.
13
WARNING
Unintentional sparking can result in fire or
electric shock.
CAUTION

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

01666-0

Table of Contents