Description Of Error Code; Error Detection For Cassette Mechanism Block; Error Detection For Cd/Changer Block - Panasonic SC-AK48 Service Manual

Table of Contents

Advertisement

11 Description of Error Code

11.1. Error Detection for Cassette Mechanism block

No.
Error
1
MODE SW detection error
2
REC INH SW detection error
3
HALF SW detection error
4
Reel Pulse detection error
5
TPS abnormal

11.2. Error Detection for CD/Changer block

No.
Error
1
REST SW detection error
2
CD tray opens automatically
3
Does not startup when
"TUNE/TIME ADJ^" button is
pressed
4
Transmission error between CD
servo LSI and micon
5
Startup fails even when you insert
CD or the selected disc tray does
not open
6
Cannot insert CD
7
Cannot eject CD
8
CD Tray closes
11.3. Error Detection for Cassette Mechanism block
No.
Error
1
POWER AMP output abnormal
Error Display
H01
Faulty operation of cassette mechanism.
Faulty contact or short-circuit of mechanism mode switch (S951, S971)
H02
Recording not possible.
Faulty contact or short-circuit of REC INH switch (S974, S975)
H03
Playback can not perform.
Faulty contact or short-circuit of HALF switch (S952, S972)
F01
The tape advances slightly and then stops.
Faulty reel pulse, faulty hole detect IC (IC951, IC971)
F02
Cassette deck will not perform TPS function.
Faulty playback EQ/recording amplifier IC (IC1101)
Error Display
F15
CD dose not function.
This error occurs when the Optical Pick Up REST SW (S701) is not detected
within the specified time (about 8 seconds)
F16
CLAMP switch (S4) NG (Check & Replace)
F17
BOTTOM switch (S5) NG (Check & Replace)
F26
CD does not function.
This error occurs when the POWER is ON for the CD block and an error is
detected after the transmission has started.
F27
Tray 1 detect switch or Tray 2 detect switch NG (Check & Replace)
F28
Tray 1 detect switch NG (Check & Replace)
F29
Check if Disc is stuck. Tray 2 detect switch NG (Confirm & Replace)
H15
CD disc tray detect switch NG (S3) (Check & Replace)
Error Display
F61
When POWER is switch on, power become off automatically.
During normal operation, if DC DET become L, PCNT shall become L and the
error display on the left shall be displayed (IC500)
33
Problem Condition
Problem Condition
Problem Condition
SA-AK48

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sa-ak48Sb-ak48