13 Description of Error Code
13.1. Abnormality Detection for DECK Mechanism
No.
Error
1
MODE SW abnormal
2
REC INH SW abnormal
3
HALF SW abnormal
4
abnormal
13.2. Abnormality detection for CD/Changer Block
No.
Error
1
REST SW abnormal
2
Transmission error between CD servo
LSI and micon
3
CLAMP SW abnormal
4
BOTTOM SW abnormal
5
POSITION SW abnormal
6
SW1 abnormal
7
SW2 abnormal
8
OPEN SW abnormal
13.3. Power Supply Related Error Detection
No.
Error
1
POWER AMP output abnormal
All manuals and user guides at all-guides.com
Error Display Problem condition
H01
Normal operation during mecha transition, MODE SW abnormal is
memorized. The content of abnormality can be confirmed in the
abnormal detection mode explained in the later section.
H02
The content of abnormality can be confirmed in the abnormal detection
mode explained in the later section.
H03
F01
Error Display Problem condition
F15
Under normal operation (Self-Diagnostic Mode inclusive), this error
occurs when the RESTSW ON is not detected within the specified time
and shall be memorized.
F26
Under normal operation (Self-Diagnostic mode inclusive), this error occurs
when the selection is set to CD and SENSE="H" is detected and
SENSE="L" is not detected within a fail safe time (20ms) after system
command transmission was sent.
F16
Refer to CR20 control specification section 5-2 [ERROR CODE] table M-
0A error is detected.
F17
Refer to CR20 control specification section 5-2 [ERROR CODE] table M-09
error is detected.
F27
Refer to CR20 control specification section 5-2 [ERROR CODE] table M-05
~ M-08 error is detected.
F28
Refer to CR20 control specification section 5-2 [ERROR CODE] table M-02
~ M-08 error is detected.
F29
H15
Refer to CR20 control specification section 5-2 [ERROR CODE] table M-01
error is detected.
Error Display Problem condition
F61
During normal operation, if DCDET 1/2 becomes "L", normal POWER
OFF process shall not ve executed, PCNT shall be switched to "L"
immediately. GOODBYE shall not be displayed and the error display F61
will be displayed instead.
2 seconds after the F61 display, ECONO shall be set to "L" and FL
display shall be turned off.
The error content shall be memorized when the abnormality occurs and
can be displayed in the C-mecha self-diagnostic mode described later.
37
SA-VK31GC / SA-VK31GS