Bit
0
1
2
3
4
5
6
7
Detailed Discussions of Bit 7
/ / / / iR1018 / iR1018J / / iR1022A / iR1022F / iR1022i / iR1022iF /
Use it to enable/disable placement of priority on recording in sub scanning direction.
place:
do not place:
*: Image B4 or shorter and that cannot be printed by division and on A4 recording paper.
5.1.5.1.2 SSSW-SW14
List of Functions
/ / / / iR1018 / iR1018J / / iR1022A / iR1022F / iR1022i / iR1022iF /
Bit
0
1
2
3
4
5
6
7
Detailed Discussions of Bit 0
/ / / / iR1018 / iR1018J / / iR1022A / iR1022F / iR1022i / iR1022iF /
Select whether to enable or disable transfer bias pressure reduction mode.
Select "Enable" to avoid image defects (black spots) produced by transfer bias leaks occurring in a low-pressure region, such as one at a high altitude. This setting
regulates the transfer bias to keep it from exceeding a predetermined level during printing.
Detailed Discussions of Bit 2
/ / / / iR1018 / iR1018J / / iR1022A / iR1022F / iR1022i / iR1022iF /
Select whether to enable or disable black belt addition mode. If the user uses paper that causes fixed toner on paper to be fused and adhered to drum, selecting
"Yes" will clean the drum by forming a black band on the drum surface during the reverse rotation which is performed after printing on 50 sheets.
Detailed Discussions of Bit 4
/ / / / iR1018 / iR1018J / / iR1022A / iR1022F / iR1022i / iR1022iF /
Select whether to enable or disable flicker reduction mode. Select "Enable" and enter a count to modify fusing temperature control to cancel fluorescent flicking
during printing.
Implementation of this mode would degrade the throughput.
Detailed Discussions of Bit 5
/ / / / iR1018 / iR1018J / / iR1022A / iR1022F / iR1022i / iR1022iF /
Select whether to enable or disable silent mode. Select "Enable" to modify the registration loop amount and thus reduce noises or squeaks the registration rollers
produce after picking paper from the individual paper inlets.
Detailed Discussions of Bit 7
/ / / / iR1018 / iR1018J / / iR1022A / iR1022F / iR1022i / iR1022iF /
Function
not used
not used
not used
not used
not used
not used
not used
priority on recording in sub scanning direction
if B4 recording paper and A4 recording paper are set and an A4 extra-long image
(*) is received, printing will be on the B4 recording paper.
if B5 horizontal recording paper and A4 recording paper are set and a B4 image is
received, printing will be by division and on B5 horizontal recording paper.
Function
Transfer bias pressure reduction mode
Not used
Black belt addition mode
Not used
Flicker reduction mode
Silent mode
Not used
Pre-rotation extension mode
T-5-16
1
-
-
-
-
-
-
-
place
T-5-17
T-5-18
1
Enable
-
Enable
-
Enable
Enable
-
Enable
0
-
-
-
-
-
-
-
do not place
0
Disable
-
Disable
-
Disable
Disable
-
Disable
Chapter 5
0013-1380
0013-1381
0013-1382
0013-1383
0013-1384
0013-1385
0013-1386
33