Table 5: Troubleshooting

FAULT
Pilot light not igniting
Pilot light not establishing
Pilot established, main burner not
lighting
Telescopic laundry arm constantly
running (on water/deck cooled
stock pot table)
Wokspout constantly running
water when in 'OFF' position
Short/long laundry arm constantly
running (when fitted with timer
operated knee valve)
To obtain further service information concerning this appliance, pleased contact;
B&S Commercial Kitchens Pty Ltd
57 Plateau Road
Reservoir VIC 3073
Tel.: + 61 3 9469 4754
POSSIBLE CAUSE
Blockage of pilot
Adjustment of pressure from flame
control
Positioning of thermocouple
Faulty thermocouple
Faulty flame failure control valve
Faulty thermocouple
Faulty flame failure control valve
Warn tap washer
Faulty 'O' ring in Wokspout
Faulty knee valve
Faulty knee valve cartridge
Fax.: + 61 3 9469 4504
Check pilot injector is not blocked
Check gas pressure to pilot as
thermocouple to the control is not
Adjust positioning of thermocouple
to ensure pilot flame is hitting
Change washers in tap assembly
Changing of 'O' ring as per service
kit and instructions provided with
Changing of knee valve cartridge
E-mail:
info@bscommercialkitchens.com
14
CHECKS
as described in servicing
instructions - pilot and flame
safeguard
described under servicing
instruction - adjustments
Check connection of the
loose
thermocouple
Contact manufacturer or
authorised service agent
Contact manufacturer or
authorised service agent
Contact manufacturer
Contact manufacturer
Contact manufacturer or
authorised service agent
appliance
Contact manufacturer or
authorised service agent
Contact manufacturer or
authorised service agent

Advertisement

Table of Contents
loading

Table of Contents