1. Specifications

Capacity
Input power
Current
EER
COP
Sensible capacity
Power factor
Moisture removal
Maximum operating current
Fan
Sound pressure level
Heat exchanger type
Enclosure
Type
Model Name-indoor unit
Power supply
Avaliable range
Rated
Cooling
Min.-Max.
Rated
Heating
Min.-Max.
Rated
Cooling
Min.-Max.
Rated
Heating
Min.-Max.
Fan
HIGH
Cooling
Rated
Heating
Cooling
Heating
Cooling
Cooling
Heating
Cooling
Heating
HIGH
MED
LOW
Type ×Q'ty
Motor output
HIGH
MED
LOW
SILENCE
Number of rows
Dimensions (H×W×D)
Tube pitch(a)x row pitch(b)
Fin spacing
Fin type
Tube outside dia.and type
Number of circuits
Material
Colour
ASYA09KLWA
kW
2.64
Btu/h
9000
kW
0.91-3.11
Btu/h
3100-10600
kW
2.93
Btu/h
10000
kW
0.82-3.37
Btu/h
2800-11500
0.710
0.10-1.24
kW
0.739
0.12-1.20
W
40
3.1
A
3.2
3.72
kW/kW
3.97
kW
2.43
0.99
%
0.99
L/h (pints/h)
0.51 (0.90)
10
A
10
520
3
m
/h
460
360
W
40
30
dB (A)
26
21
mm
mm
mm
Hydrophilic aluminium
φ5,innergroove copper tube
mm
- 2 -
Wall mounted
Inverter heat pump
ASYA12KLWA
1ɸ , 230V, 50Hz
198~264V
3.52
12000
1.11-4.16
3800-14200
3.81
13000
1.08-4.22
3700-14400
1.237
0.13-1.58
0.964
0.10-1.58
40
5.4
4.2
2.84
3.95
2.64
0.99
0.99
1.24 (2.18)
10
10
600
500
360
Cross flow fan×1
13
40
34
26
22
2
595x273x23.2
19.5x11.6
1.2
4
HIPS
White
1. Specifications