4. Refrigerant circuit
4-1. Models: AOYA09KLWA and AOYA12KLWA
Indoor Heat
Exchanger
T1-Sensor
(Indoor)
T2-Sensor
(Evaporator)
4-1. Models: AOYA09KLWA and AOYA12KLWA
Liquid side
2-Way Valve
Gas side
3-Way Valve
- 24 -
Throttle device
(Valve/Capilliary Tube)
4- Way
Valve
Muffler
T4-Sensor
Muffler
(Outdoor)
T5-Sensor(Discharge)
Heating
Cooling
Compressor
Outdoor Heat
Exchanger
T3-Sensor
(Condensor)