Connecting The Refrigerator - Dometic RUC Series Installation And Operating Manual

Compressor refrigerator
Table of Contents

Advertisement

RUC5208X, RUC6408X, RUC8408X
8

Connecting the refrigerator

8.1
Connecting the refrigerator to 12 – 24 V
A
NOTICE!
To avoid voltage drops and loss of performance, keep the
connection cable as short as possible and uninterrupted.
Therefore avoid additional switches, plugs or power strips.
The refrigerator can be operated with a 12 V or 24 V DC voltage supply.
For safety reasons, the refrigerator is equipped with an electronic system to prevent
the polarity being reversed. This protects the refrigerator against reversed polarity
when connecting to a battery and against short circuiting.
To protect the battery, the refrigerator switches off automatically if the voltage is
insufficient (see table below).
Cut-off voltage
Cut-in voltage
j
Ø/mm²
14
10
6
2
0
0
2
4
➤ Determine the required cross section of the cable in relation to the cable length
according to the figure above.
EN
12 V
6
8
10
12
Connecting the refrigerator
12 V
10.4 V
11.7 V
14
16
18 20 22 24 26 28
24 V
22.8 V
24.2 V
24 V
l/m