Dometic RM2652 Installation And Operating Instructions Manual

Dometic RM2652 Installation And Operating Instructions Manual

Refrigerator for lp-gas and electric operation

Advertisement

REFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATION
RM2652
RM2852
FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. Don't touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WARNING: Improper installation,
adjustment, alteration, service or
maintenance can cause injury or
property damage. Refer to this
manual. For assistance or additional
information consult a qualified
installer, service agency or the gas
supplier.
USA
Service Office
Dometic Corporation
2320 Industrial Parkway
Elkhart, IN 46515
Phone: 574-294-2511
822701206 MO-FO 0327 (French 3309599.003)
INSTALLATION AND
®
OPERATING INSTRUCTIONS
Corporate Office
2320 Industrial Parkway Elkhart, IN 46515
For Service Center Assistance
Call: 800-544-4881
Contents:
Installation
Operating Instructions
Maintenance & Service
Pour votre sécurité
Si vous sentez une odeur de gaz:
1. Ouvrez les fenêtres.
2. Ne touchez à aucun interrupteur.
3. Éteignez toute flamme nue.
4. Avertissez immédiatement votre fournis-
seur de gaz.
Pour votre sécurité
Ne pas entreposer ni utiliser de l'essence ni
d'autres vapeurs ou liquides inflammables à
proximité de cet appareil ou de tout autre
appareil.
Avertissement: Une installation, un réglage,
une modification, une réparation ou un
entretien non conforme aux normes peut
entraîner des blessures ou des dommages
matériels. Lisez attentivement le mode d'em-
ploi fourni avec l'appareil. Pour obtenir de
l'aide ou des renseignements supplémentai-
res, consultez un installateur ou un service
d'entretien qualifié ou le fournisseur de gaz.
®
Page
4
8
12
CANADA
Dometic Distribution Inc.
866 Langs Drive
Cambridge, Ontario
N3H 2N7 Canada
Phone: 519-653-4390

Advertisement

Table of Contents
loading

Summary of Contents for Dometic RM2652

  • Page 1 Corporate Office 2320 Industrial Parkway Elkhart, IN 46515 For Service Center Assistance Call: 800-544-4881 Contents: Page Installation Operating Instructions Maintenance & Service ® CANADA Dometic Distribution Inc. 866 Langs Drive Cambridge, Ontario N3H 2N7 Canada Phone: 519-653-4390...
  • Page 3 Flexible cord AUTO FIG. 2 12V DC 12 volt Terminal block Drain water hose Inlet fitting Refrigerator control panel CHECK AUTOMATIC REFRIGERATOR TEMPERATURE CONTROL Heater Flue baffle Protection cover Screw for protection cover Burner jet Manual gas shutoff valve LEGEND 1.
  • Page 4 11 inches water column. When testing the gas supply system at test pressures in excess of 1/2 psi, the refrigerator and its individual shutoff valve must be disconnected from the gas supply piping system.
  • Page 5: Securing The Refrigerator

    This refrigerator model is not designed for 12 volt DC operation of the cooling system; however, a continuous 12 volt DC must be supplied to the refrigerator to oper- ate the controls. Use a minimum of a 14 gauge wire between the battery and refrigerator to supply the con- trol voltage.
  • Page 6: Drain Water Hose

    2. Once the lower front strip is slipped under the hinge, the part is possible to swing into place as shown in FIG. 6. 3. Secure the refrigerator and the lower front strip with two screws: One screw through the hinge, and on the opposite side one screw through the lower front strip.
  • Page 7 N: See NOTE: Clearance “N” below. NOTE: Clearance “M” is between the rearmost part of the refrigerator and the wall behind the refrigerator. NOTE: Clearance “N” is the distance between the bot- tom of the lower side vent to the roof material. For ven- tilation height, see table VENTILATION HEIGHTS.
  • Page 8: Operating Instructions

    If the refrigerator is operated when it is not level and the ve- hicle is not moving, liquid ammonia will accumulate in sections of the evaporator tubing. This will slow the cir- culation of hydrogen and ammonia gas, or in severe cases, completely block it, resulting in a loss of cooling.
  • Page 9: Auto Mode

    AC is not available), it may take longer than 45 sec- onds to allow air to be purged from the gas line. If the refrigerator has not been used for a long time or the LP tanks have just been refilled, air may be trapped in the supply lines.
  • Page 10 OFF button (1) to the OFF and then ON position. The control system will attempt a new ignition sequence. If the refrigerator has not been used for a long time or the LP tanks have just been refilled, air may be trapped in the supply lines.
  • Page 11: How To Use The Refrigerator

    For faster ice making, the trays should be placed in direct contact with the bottom of the freezer compartment. Refrigerator volume. Total refrigerated volume is 6 cu.ft. for the model RM2652. Total refrigerated volume is 8 cu.ft. for the model RM2852. DEFROSTING Shut off the refrigerator by pressing the main power ON/OFF button to the UP (OFF) position.
  • Page 12: Gas Equipment Assembly

    Refer to section INSTALLATION, page 4 to 8. 2. PERIODIC MAINTENANCE To keep your Dometic refrigerator operating efficiently and safely, periodic inspection and cleaning of several components once or twice a year is recommended. A. It is important to keep the area at the back of the refrigerator clean.
  • Page 13: Troubleshooting

    B. Check all connections in the LP gas system (at the back of the refrigerator) for gas leaks. The LP gas supply must be turned on. Apply a non-corrosive bubble solution to all LP gas connections. The appearance of bubbles indicates a leak and...
  • Page 14 38-11/16 38-5/8 SPARE PARTS The following list is a list of commonly used parts, which should be available, if required, from your Dometic Ser- vice Center. A = RM2652; B = RM2852. Part No. Description 200 74 19-21/7 A B Jet, No. 58...
  • Page 15 CERTIFIED VENT SYSTEM KITS REFRIGERATOR MODEL RM2652 RM2852 * Fill in “XXX” with color code numbers. For color codes, contact your supplier. For further information contact your dealer or distributor. COMPONENTS Roof Base Roof Cover Lower Side Vent PART NO.
  • Page 16: Positioning Of Shelves

    Put a screwdriver into the slot of the shelf lock. Turn the screwdriver counterclockwise. Remove the shelf locks from the wire shelf. Slide the wire shelf to the left. The right-hand side of the shelf will come loose. Lower the right-hand side of the wire shelf and let the left-hand side slide out of the holes in the wall.
  • Page 17 RM2652, RM2852...
  • Page 20 MO-FO 0327...

This manual is also suitable for:

Rm2852