Item
Condition
6. DQT
1) TEST CH: 1
Deviation
Deviation meter fi lter
[Wide]
LPF: 3kHz
HPF: OFF
PTT: ON
7. QT
1) TEST CH: 1
Deviation
Deviation meter fi lter
[Wide]
LPF: 3kHz
HPF: OFF
PTT: ON
8. DTMF
1) TEST CH: 1
Deviation
Deviation meter fi lter
[Wide]
LPF: 15kHz
HPF: OFF
PTT: ON
9. MSK
1) TEST CH: 1
Deviation
Deviation meter fi lter
[Wide]
LPF: 15kHz
HPF: OFF
PTT: ON
Note: Regarding deviation alignment item, narrow value is calculated from wide alignment value.
Receiver Section
Item
Condition
1. Sensitivity
1) TEST CH: Low, Center, High
(Semiauto-
(3 points)
matic)
SSG otuput : –90dBm
(7.08µV)
SSG MOD: 3.0kHz
48
ADJUSTMENT
ADJUSTMENT
Measurement
Test-
Unit
Terminal
equipment
Power
ANT
meter
Deviation
meter
Oscilloscope
Measurement
Test-
Unit
Terminal
equipment
SSG
ANT
DVM
Oscilloscope
Adjustment
Unit
Parts
Method
FPU
0.75kHz
0.75kHz
3.0kHz
3.0kHz
Adjustment
Unit
Parts
Method
FPU
Press [Start]
(Auto tuning)
Specifi cations / Remarks
±40Hz
±40Hz
±100Hz
±100Hz
Specifi cations / Remarks