Kenwood NX-900 Service Manual page 60

800mhz digital transceiver
Hide thumbs Also See for NX-900:
Table of Contents

Advertisement

NX-900
■ Necessary Deviation adjustment item for each signaling and mode
The following shows the necessary adjustment items for each signaling deviation. Please read the following table like the following example. In the
case of the signaling "QT (Wide 5k)", this signaling is composed of three elements [Balance, Maximum Deviation (Analog Wide 5k) and QT Deviation
(Wide 5k)]. Please adjust Balance and Maximum Deviation (Analog Wide 5k) before adjusting QT Deviation (Wide 5k).
Mode
Signaling
Step1. Balance adjust
Audio
Step2. Maximum Deviation
(Analog Wide 5k)
Step1. Balance adjust
Step2. Maximum Deviation
QT
(Analog Wide 5k)
Step3. QT Deviation
(Analog Wide 5k)
Step1. Balance adjust
Step2. Maximum Deviation
DQT
(Analog Wide 5k)
Step3. DQT Deviation
(Analog Wide 5k)
Step1. Balance adjust
Analog
Step2. Maximum Deviation
LTR
(Analog Wide 5k)
Step3. LTR Deviation
(Analog Wide 5k)
Step1. Balance adjust
Step2. Maximum Deviation
DTMF
(Analog Wide 5k)
Step3. DTMF Deviation
(Analog Wide 5k)
Step1. Balance adjust
Step2. Maximum Deviation
MSK
(Analog Wide 5k)
(FleetSync)
Step3. MSK Deviation
(Analog Wide 5k)
Audio
-
NXDN
CWID
-
• Balance is common with all the above deviation adjustments. If Balance (Transmitter Section 5) has already adjusted, please skip Step1 and adjust from
Step2.
• Maximum Deviation (Analog Wide 5k/Wide 4k/Narrow) is common with all the analog signaling deviations and CWID Deviation (NXDN Very Narrow). If Bal-
ance and Maximum Deviation (Analog Wide 5k/Wide 4k/Narrow) (Transmitter Section 7) have already adjusted, please skip Step2 and adjust from Step3.
60
ADJUSTMENT
Wide 5k
Step1. Balance adjust
Step2. Maximum Deviation
(Analog Wide 4k)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog Wide 4k)
Step3. QT Deviation
(Analog Wide 4k)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog Wide 4k)
Step3. DQT Deviation
(Analog Wide 4k)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog Wide 4k)
Step3. LTR Deviation
(Analog Wide 4k)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog Wide 4k)
Step3. DTMF Deviation
(Analog Wide 4k)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog Wide 4k)
Step3. MSK Deviation
(Analog Wide 4k)
-
-
Necessary adjustment and order
Wide 4k
Step1.Balance adjust
Step2. Maximum Deviation
(Analog Narrow)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog Narrow)
Step3. QT Deviation
(Analog Narrow)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog Narrow)
Step3. DQT Deviation
(Analog Narrow)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog Narrow)
Step3. LTR Deviation
(Analog Narrow)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog Narrow)
Step3. DTMF Deviation
(Analog Narrow)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog Narrow)
Step3. MSK Deviation
(Analog Narrow)
Step1. Balance adjust
Step2. Maximum Deviation
(NXDN Narrow)
-
Narrow
Very Narrow
-
-
-
-
-
-
Step1. Balance adjust
Step2. Maximum Deviation
(NXDN Very Narrow)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog Narrow)
Step3. CW ID Deviation
(NXDN Very Narrow)

Advertisement