Kenwood NX-900 Service Manual page 57

800mhz digital transceiver
Hide thumbs Also See for NX-900:
Table of Contents

Advertisement

Item
Panel tuning mode
Maximum
1) Adj item: [Aw ADEV]
Deviation
Adjust: [✳✳✳✳]
(Analog) *3
2) Adj item:
[AnL ADEV]→
[Wide 5k]
[AnH ADEV]→
[AnL ADEV] (TA)→
[AnH ADEV] (TA)
Adjust: [✳✳✳✳]
PTT: ON
Press [ ] key to store
the adjustment value.
*3: Refer to the "Necessary Deviation adjustment item for each signaling and mode" table on page 60.
Regarding Maximum Deviation (Analog), it is common with the adjustment of all analog signalings.
8. QT
1) Adj item: [An QT]
Deviation
Adjust: [✳✳✳✳]
*4
Deviation meter
LPF: 3kHz
[Narrow]
HPF: OFF
PTT: ON
Press [ ] key to store
the adjustment value.
[Wide 4k]
1) Adj item: [As QT]
Adjust: [✳✳✳✳]
PTT: ON
Press [ ] key to store
the adjustment value.
[Wide 5k]
1) Adj item: [Aw QT]
Adjust: [✳✳✳✳]
PTT: ON
Press [ ] key to store
the adjustment value.
9. DQT
1) Adj item: [An DQT]
Deviation
Adjust: [✳✳✳✳]
*4
Deviation meter
LPF: 3kHz
[Narrow]
HPF: OFF
PTT: ON
Press [ ] key to store
the adjustment value.
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [Maximum
Deviation
Deviation (Analog
meter
Wide 5k)]
Oscilloscope
2) Adj item: [Low],
[High], [Low (TA)],
[High (TA)]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item: [QT Devia-
Deviation
tion (Narrow)]
meter
Deviation meter
Oscilloscope
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [QT Devia-
tion (Wide 4k)]
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [QT Devia-
tion (Wide 5k)]
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [DQT
Deviation (Narrow)]
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Measurement
Test-
Unit Terminal Unit
ANT
ANT
NX-900
Adjustment
Specifi cations /
Parts
Method
[Panel
4200Hz
4150~4250Hz
tuning
Write the value as
mode]
followings.
[PC test mode]
[ ],[ ]
498 (Reference
Press [Apply All]
value)
button to store the
[PC test
adjustment value
mode]
Deviation meter
after all adjustment
[ ],[ ]
LPF: 15kHz
point was adjusted.
HPF: OFF
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press
[Transmit] button
[Panel
Write the value as
0.30~0.40kHz
tuning
followings.
mode]
513 (Reference
[ ],[ ]
value)
[PC test
mode]
[ ],[ ]
0.55~0.65kHz
0.70~0.80kHz
Write the value as
0.30~0.40kHz
followings.
430 (Reference
value)
Remarks
57

Advertisement