Chicago Electric 67411 Set Up And Operating Instructions Manual page 15

8-1/4” compound miter saw
Table of Contents

Advertisement

Cover Plate Screw
Figure 3
3.
Loosen but do not remove the Cover
Plate Screw. Rotate the Blade Guard
(12) up and out of the way to expose
the Blade.
Figure 4
4.
Stop the Blade rotation by holding
the Spanner (106) in the two holes on
either side of the center of the Blade.
Unthread and remove the Arbor Bolt
(17), the Outer Flange (18), and the
Blade (19).
SKU 67411
For technical questions, please call 1-800-444-3353.
note: The Arbor Bolt has a left hand
Rotate Blade
Guard up and
out of the way.
note: Pay attention to the pieces re-
5.
6.
note: Tighten the Arbor Bolt using moder-
7.
8.
thread, so it loosens by turning clock-
wise.
moved, their position and the direc-
tion of the face. Wipe the Blade
collars clean of any sawdust before
installing the new Blades.
Figure 5
Reinstall a new Blade on the Inner
Flange (20). Be sure to match the
direction marked on the new blade
with the direction marked on the saw
Blade Housing.
Replace the Outer Flange and Arbor
Bolt. Tighten the Arbor Bolt securely
using the screwdriver by turning it
counterclockwise.
ate force, but do not overtighten.
Rotate the Blade Guard back into
place and tighten the Cover Plate
Screw using the screwdriver by
turning it clockwise.
Pull out the Locking Pin and lower the
saw head until it locks in place in the
lowered position.