Encoder Feedback Control Parameter List - Mitsubishi Electric FR-A7AP Instruction Manual

Plug-in option, orientation control, encoder feedback control, vector control
Hide thumbs Also See for FR-A7AP:
Table of Contents

Advertisement

ENCODER FEEDBACK CONTROL
4.3

Encoder Feedback Control Parameter List

Fitting the FR-A7AP adds the following parameters for encoder feedback operation.
Refer to the inverter manual (applied) for details of parameter.
Parameter
Number
359
Encoder rotation direction
367
Speed feedback time
368
Feedback gain
369
Number of encoder pulses
374
Overspeed detection level
Encoder signal loss detection
376
enable/disable selection
26
Name
Setting Range
0 to 400Hz, 9999
Increments
0, 1
0.01Hz
0 to 100
0.1
0 to 4096
0 to 400Hz
0.01Hz
0, 1
Initial Value
1
1
9999
1
1
1024
140Hz
1
0

Advertisement

Table of Contents
loading

Table of Contents