INSTALLATION
(3) Motor used and switch setting
Motor
Mitsubishi standard motor
Mitsubishi high efficiency
motor
Mitsubishi constant-
torque motor
Dedicated motor
Other manufacturer motor
*1
Set according to the motor encoder used.
*2
Choose a power supply for encoder according to the encoder used (5V/12V/15V/24V).
8
Encoder Specification
Selection Switch (SW1)
SF-JR
Differential
SF-HR
Differential
Others
SF-JRCA
Differential
SF-HRCA
Differential
Others
SF-V5RU
Complimentary
SF-VR
Differential
Terminating Resistor
Selection Switch (SW2)
*1
*1
*1
Power
Specifications
ON
5V
ON
5V
*1
ON
5V
ON
5V
*1
OFF
12V
ON
5V
*1
*2
*1
*1
*1