Maintenance - Husqvarna S 36 Operator's Manual

Propane
Hide thumbs Also See for S 36:
Table of Contents

Advertisement

Available languages

Available languages

1. Check that the emission sensor indicator on the
instrument panel is lit.
LAMBDA
SENSOR
2. Shut off the gas valve on the tank.
3. Turn the key switch to "0"
4. Turn the "COUPLING" to "OFF".
5. Evacuate the area and let it ventilate.
6. Make sure that the indicator is not lit and then restart
the dust extractor.
Muffler
WARNING: Never use a product without a
muffler, or with a faulty muffler. A damaged
muffler may substantially increase the noise
level and the fire hazard. Keep firefighting
equipment nearby.
The muffler gets very hot during and after use. This also
applies during idling. Be aware of the fire hazard,
especially when working near flammable substances
and/or vapours. The muffler is designed to keep noise
Maintenance schedule S 36 Propane / T 8600 Propane
Note: See engine manufacturer manual for service
information regarding the engine.
Operation
Check & add engine oil
Check for loose or lost fasteners
Check for oil leakage
Inspect fuel hose and connections
Check engine dust filter
Clean engine dust filter. See Note 1
Inspect throttle & wire
Change engine oil. See Note 2
Change engine oil filter. See Note 3
Inspect battery and battery connections
Inspect magnetic clutch
518 - 003 - 07.06.2018
COUPLING
1
0
START
OFF
ON
FUSE
20A

MAINTENANCE

levels to a minimum and to direct exhaust fumes away
from the user.
Check regularly that the muffler is complete and secured
correctly.
To clean the filter
CAUTION: If suction remains poor, the pre-
filter needs to be replaced. If suction still
remains poor afterwards, the HEPA filters
need to be replaced. See instructions in
change the HEPA filter on page 10 .
The filter must be cleaned from time to time. This must
be done before changing the plastic bag collection
system and should also be done when work is
completed or when there is poor suction.
1. While running the dust extractor, seal the inlet using
the inlet plug or the inlet valve (T 8600 Propane).
2. Let the dust extractor build up vacuum for 5
seconds, then quickly push and hold down the Jet
Pulse handle for 5 seconds.
3. Repeat step 2 five times. It is important to let the
dust extractor rebuild the vacuum in between every
repetition.
4. If suction remains poor, the filter should be replaced.
Only replace plastic bag after cleaning the filter.
Daily
8 Hrs.
X
X
X
X
X
X
X
50 hrs.
X
X
X
X
X
To
9